<?xml version="1.0" encoding="utf-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD JATS (Z39.96) Journal Publishing DTD v1.1d3 20150301//EN" "http://jats.nlm.nih.gov/publishing/1.1d3/JATS-journalpublishing1.dtd">
<article article-type="research-article" dtd-version="1.1d3" xml:lang="en" xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">
<front>
<journal-meta>
<journal-id journal-id-type="nlm-ta">PLoS ONE</journal-id>
<journal-id journal-id-type="publisher-id">plos</journal-id>
<journal-id journal-id-type="pmc">plosone</journal-id>
<journal-title-group>
<journal-title>PLOS ONE</journal-title>
</journal-title-group>
<issn pub-type="epub">1932-6203</issn>
<publisher>
<publisher-name>Public Library of Science</publisher-name>
<publisher-loc>San Francisco, CA USA</publisher-loc>
</publisher>
</journal-meta>
<article-meta>
<article-id pub-id-type="doi">10.1371/journal.pone.0232100</article-id>
<article-id pub-id-type="publisher-id">PONE-D-19-23799</article-id>
<article-categories>
<subj-group subj-group-type="heading">
<subject>Research Article</subject>
</subj-group>
<subj-group subj-group-type="Discipline-v3">
<subject>Biology and life sciences</subject><subj-group><subject>Neuroscience</subject><subj-group><subject>Brain mapping</subject><subj-group><subject>Magnetoencephalography</subject></subj-group></subj-group></subj-group></subj-group><subj-group subj-group-type="Discipline-v3">
<subject>Research and analysis methods</subject><subj-group><subject>Imaging techniques</subject><subj-group><subject>Neuroimaging</subject><subj-group><subject>Magnetoencephalography</subject></subj-group></subj-group></subj-group></subj-group><subj-group subj-group-type="Discipline-v3">
<subject>Biology and life sciences</subject><subj-group><subject>Neuroscience</subject><subj-group><subject>Neuroimaging</subject><subj-group><subject>Magnetoencephalography</subject></subj-group></subj-group></subj-group></subj-group><subj-group subj-group-type="Discipline-v3">
<subject>Medicine and health sciences</subject><subj-group><subject>Diagnostic medicine</subject><subj-group><subject>Diagnostic radiology</subject><subj-group><subject>Magnetic resonance imaging</subject></subj-group></subj-group></subj-group></subj-group><subj-group subj-group-type="Discipline-v3">
<subject>Research and analysis methods</subject><subj-group><subject>Imaging techniques</subject><subj-group><subject>Diagnostic radiology</subject><subj-group><subject>Magnetic resonance imaging</subject></subj-group></subj-group></subj-group></subj-group><subj-group subj-group-type="Discipline-v3">
<subject>Medicine and health sciences</subject><subj-group><subject>Radiology and imaging</subject><subj-group><subject>Diagnostic radiology</subject><subj-group><subject>Magnetic resonance imaging</subject></subj-group></subj-group></subj-group></subj-group><subj-group subj-group-type="Discipline-v3">
<subject>Biology and life sciences</subject><subj-group><subject>Anatomy</subject><subj-group><subject>Head</subject></subj-group></subj-group></subj-group><subj-group subj-group-type="Discipline-v3">
<subject>Medicine and health sciences</subject><subj-group><subject>Anatomy</subject><subj-group><subject>Head</subject></subj-group></subj-group></subj-group><subj-group subj-group-type="Discipline-v3">
<subject>Biology and life sciences</subject><subj-group><subject>Neuroscience</subject><subj-group><subject>Cognitive science</subject><subj-group><subject>Cognition</subject><subj-group><subject>Memory</subject><subj-group><subject>Face recognition</subject></subj-group></subj-group></subj-group></subj-group></subj-group></subj-group><subj-group subj-group-type="Discipline-v3">
<subject>Biology and life sciences</subject><subj-group><subject>Neuroscience</subject><subj-group><subject>Learning and memory</subject><subj-group><subject>Memory</subject><subj-group><subject>Face recognition</subject></subj-group></subj-group></subj-group></subj-group></subj-group><subj-group subj-group-type="Discipline-v3">
<subject>Biology and life sciences</subject><subj-group><subject>Neuroscience</subject><subj-group><subject>Cognitive science</subject><subj-group><subject>Cognitive psychology</subject><subj-group><subject>Perception</subject><subj-group><subject>Face recognition</subject></subj-group></subj-group></subj-group></subj-group></subj-group></subj-group><subj-group subj-group-type="Discipline-v3">
<subject>Biology and life sciences</subject><subj-group><subject>Psychology</subject><subj-group><subject>Cognitive psychology</subject><subj-group><subject>Perception</subject><subj-group><subject>Face recognition</subject></subj-group></subj-group></subj-group></subj-group></subj-group><subj-group subj-group-type="Discipline-v3">
<subject>Social sciences</subject><subj-group><subject>Psychology</subject><subj-group><subject>Cognitive psychology</subject><subj-group><subject>Perception</subject><subj-group><subject>Face recognition</subject></subj-group></subj-group></subj-group></subj-group></subj-group><subj-group subj-group-type="Discipline-v3">
<subject>Biology and life sciences</subject><subj-group><subject>Anatomy</subject><subj-group><subject>Head</subject><subj-group><subject>Face</subject></subj-group></subj-group></subj-group></subj-group><subj-group subj-group-type="Discipline-v3">
<subject>Medicine and health sciences</subject><subj-group><subject>Anatomy</subject><subj-group><subject>Head</subject><subj-group><subject>Face</subject></subj-group></subj-group></subj-group></subj-group><subj-group subj-group-type="Discipline-v3">
<subject>Research and analysis methods</subject><subj-group><subject>Research assessment</subject><subj-group><subject>Research validity</subject></subj-group></subj-group></subj-group><subj-group subj-group-type="Discipline-v3">
<subject>Research and analysis methods</subject><subj-group><subject>Imaging techniques</subject><subj-group><subject>Neuroimaging</subject></subj-group></subj-group></subj-group><subj-group subj-group-type="Discipline-v3">
<subject>Biology and life sciences</subject><subj-group><subject>Neuroscience</subject><subj-group><subject>Neuroimaging</subject></subj-group></subj-group></subj-group><subj-group subj-group-type="Discipline-v3">
<subject>Physical sciences</subject><subj-group><subject>Mathematics</subject><subj-group><subject>Applied mathematics</subject><subj-group><subject>Algorithms</subject></subj-group></subj-group></subj-group></subj-group><subj-group subj-group-type="Discipline-v3">
<subject>Research and analysis methods</subject><subj-group><subject>Simulation and modeling</subject><subj-group><subject>Algorithms</subject></subj-group></subj-group></subj-group></article-categories>
<title-group>
<article-title>A comparison of automated and manual co-registration for magnetoencephalography</article-title>
<alt-title alt-title-type="running-head">MEG coregistration</alt-title>
</title-group>
<contrib-group>
<contrib contrib-type="author" corresp="yes" xlink:type="simple">
<contrib-id authenticated="true" contrib-id-type="orcid">http://orcid.org/0000-0002-6565-4481</contrib-id>
<name name-style="western">
<surname>Houck</surname>
<given-names>Jon M.</given-names>
</name>
<role content-type="http://credit.casrai.org/">Conceptualization</role>
<role content-type="http://credit.casrai.org/">Formal analysis</role>
<role content-type="http://credit.casrai.org/">Methodology</role>
<role content-type="http://credit.casrai.org/">Software</role>
<role content-type="http://credit.casrai.org/">Writing – original draft</role>
<role content-type="http://credit.casrai.org/">Writing – review &amp; editing</role>
<xref ref-type="aff" rid="aff001"><sup>1</sup></xref>
<xref ref-type="aff" rid="aff002"><sup>2</sup></xref>
<xref ref-type="corresp" rid="cor001">*</xref>
</contrib>
<contrib contrib-type="author" xlink:type="simple">
<name name-style="western">
<surname>Claus</surname>
<given-names>Eric D.</given-names>
</name>
<role content-type="http://credit.casrai.org/">Funding acquisition</role>
<role content-type="http://credit.casrai.org/">Project administration</role>
<role content-type="http://credit.casrai.org/">Writing – review &amp; editing</role>
<xref ref-type="aff" rid="aff001"><sup>1</sup></xref>
</contrib>
</contrib-group>
<aff id="aff001"><label>1</label> <addr-line>Mind Research Network, Albuquerque, New Mexico, United States of America</addr-line></aff>
<aff id="aff002"><label>2</label> <addr-line>Center on Alcoholism, Substance Abuse and Addictions, University of New Mexico, Albuquerque, New Mexico, United States of America</addr-line></aff>
<contrib-group>
<contrib contrib-type="editor" xlink:type="simple">
<name name-style="western">
<surname>Johnson</surname>
<given-names>Blake</given-names>
</name>
<role>Editor</role>
<xref ref-type="aff" rid="edit1"/>
</contrib>
</contrib-group>
<aff id="edit1"><addr-line>Australian Research Council Centre of Excellence in Cognition and its Disorders, AUSTRALIA</addr-line></aff>
<author-notes>
<fn fn-type="conflict" id="coi001">
<p>The authors have declared that no competing interests exist.</p>
</fn>
<corresp id="cor001">* E-mail: <email xlink:type="simple">jhouck@unm.edu</email></corresp>
</author-notes>
<pub-date pub-type="epub">
<day>29</day>
<month>4</month>
<year>2020</year>
</pub-date>
<pub-date pub-type="collection">
<year>2020</year>
</pub-date>
<volume>15</volume>
<issue>4</issue>
<elocation-id>e0232100</elocation-id>
<history>
<date date-type="received">
<day>22</day>
<month>8</month>
<year>2019</year>
</date>
<date date-type="accepted">
<day>7</day>
<month>4</month>
<year>2020</year>
</date>
</history>
<permissions>
<copyright-year>2020</copyright-year>
<copyright-holder>Houck, Claus</copyright-holder>
<license xlink:href="http://creativecommons.org/licenses/by/4.0/" xlink:type="simple">
<license-p>This is an open access article distributed under the terms of the <ext-link ext-link-type="uri" xlink:href="http://creativecommons.org/licenses/by/4.0/" xlink:type="simple">Creative Commons Attribution License</ext-link>, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.</license-p>
</license>
</permissions>
<self-uri content-type="pdf" xlink:href="info:doi/10.1371/journal.pone.0232100"/>
<abstract>
<p>Magnetoencephalography (MEG) is a neuroimaging technique that accurately captures the rapid (sub-millisecond) activity of neuronal populations. Interpretation of functional data from MEG relies upon registration to the participant’s anatomical MRI. The key remaining step is to transform the participant’s MRI into the MEG head coordinate space. Although both automated and manual approaches to co-registration are available, the relative accuracy of two approaches has not been systematically evaluated. The goal of the present study was to compare the accuracy of manual and automated co-registration. Resting MEG and T1-weighted MRI data were collected from 90 participants. Automated and manual co-registration were performed on the same subjects, and the inter-method reliability of the two methods assessed using the intra-class correlation. Median co-registration error for both methods was within acceptable limits. Inter-method reliability was in the “good” range for co-registration error, and the “good” to “excellent” range for translation and rotation. These results suggest that the output of the automated co-registration procedure is comparable to that achieved using manual co-registration.</p>
</abstract>
<funding-group>
<award-group id="award001">
<funding-source>
<institution-wrap>
<institution-id institution-id-type="funder-id">http://dx.doi.org/10.13039/100000027</institution-id>
<institution>National Institute on Alcohol Abuse and Alcoholism</institution>
</institution-wrap>
</funding-source>
<award-id>K01AA021431</award-id>
<principal-award-recipient>
<contrib-id authenticated="true" contrib-id-type="orcid">http://orcid.org/0000-0002-6565-4481</contrib-id>
<name name-style="western">
<surname>Houck</surname>
<given-names>Jon M.</given-names>
</name>
</principal-award-recipient>
</award-group>
<award-group id="award002">
<funding-source>
<institution-wrap>
<institution-id institution-id-type="funder-id">http://dx.doi.org/10.13039/100000027</institution-id>
<institution>National Institute on Alcohol Abuse and Alcoholism</institution>
</institution-wrap>
</funding-source>
<award-id>R01AA023665</award-id>
<principal-award-recipient>
<name name-style="western">
<surname>Claus</surname>
<given-names>Eric D.</given-names>
</name>
</principal-award-recipient>
</award-group>
<funding-statement>JMH K01AA021431 National Institute on Alcohol Abuse and Alcoholism <ext-link ext-link-type="uri" xlink:href="https://www.niaaa.nih.gov" xlink:type="simple">https://www.niaaa.nih.gov</ext-link> EDC R01AA023665 National Institute on Alcohol Abuse and Alcoholism <ext-link ext-link-type="uri" xlink:href="https://www.niaaa.nih.gov" xlink:type="simple">https://www.niaaa.nih.gov</ext-link> The funders had no role in study design, data collection and analysis, decision to publish, or preparation of the manuscript.</funding-statement>
</funding-group>
<counts>
<fig-count count="3"/>
<table-count count="1"/>
<page-count count="9"/>
</counts>
<custom-meta-group>
<custom-meta id="data-availability">
<meta-name>Data Availability</meta-name>
<meta-value>The raw source data cannot be shared publicly because the study relies upon head shape and T1-weighted structural MRI data. These are generally considered identifiable data, and cannot be shared according to the guidance of The Institutional Review Board of the University of New Mexico. The error data used in the computation of the intra-class correlations (ICCs) as well as de-faced MRIs are available at <ext-link ext-link-type="uri" xlink:href="https://doi.org/10.35092/yhjc.11991546" xlink:type="simple">https://doi.org/10.35092/yhjc.11991546</ext-link> but these are not the raw study data used in this manuscript. The Methods provide enough detail for interested researchers to replicate the analyses in a similar population.</meta-value>
</custom-meta>
</custom-meta-group>
</article-meta>
</front>
<body>
<sec id="sec001" sec-type="intro">
<title>Introduction</title>
<p>Magnetoencephalography (MEG) is a neuroimaging technique that accurately captures the rapid (sub-millisecond) activity of neuronal populations. Indeed, MEG can only detect signal from the synchronous firing of neuronal populations in a cortical patch of approximately 10 mm<sup>2</sup> or larger [<xref ref-type="bibr" rid="pone.0232100.ref001">1</xref>], making it essentially a network-detection technique. Due to a relative scarcity of reimbursable MEG-based clinical procedures, historically MEG was available at only a relatively limited number of cutting-edge research and clinical institutions [<xref ref-type="bibr" rid="pone.0232100.ref002">2</xref>]. However, interest in MEG has grown as the technique’s potential has been revealed over the past four decades, with increased recognition of MEG as a means of directly evaluating neuronal networks and their relevance to a range of disorders as well as to typical cognitive and affective processes.</p>
<p>As is the case for other functional neuroimaging approaches, interpretation of functional data from MEG relies upon registration to an anatomical or template MRI [<xref ref-type="bibr" rid="pone.0232100.ref003">3</xref>]. Because the data for the two modalities are collected on different scanners and therefore in different coordinate spaces [<xref ref-type="bibr" rid="pone.0232100.ref004">4</xref>], the procedure for MRI-MEG co-registration is somewhat involved. Typically during preparation for an MEG scan, three to five head position coils are affixed to the participant’s scalp, and then a 3D digitizing pen is used to digitize important points including the coil locations, anatomical landmarks that typically include the nasion and preauricular points, as well as a detailed headshape using approximately 150 points (<xref ref-type="fig" rid="pone.0232100.g001">Fig 1</xref>). The headshape points are collected primarily from the brow, bridge of the nose, and skull, avoiding the lower jaw and cartilaginous or fatty tissue that would be expected to shift when the participant moves or might be compressed by the head coil during the participant’s MRI scan. Because this preparation process can be somewhat labor-intensive and subject to variability in technician skill, alternatives such as use of a bite bar [<xref ref-type="bibr" rid="pone.0232100.ref005">5</xref>], 3-D camera [<xref ref-type="bibr" rid="pone.0232100.ref006">6</xref>], or 3-D laser scanner [<xref ref-type="bibr" rid="pone.0232100.ref007">7</xref>] have also been explored but are not widely used.</p>
<fig id="pone.0232100.g001" position="float">
<object-id pub-id-type="doi">10.1371/journal.pone.0232100.g001</object-id>
<label>Fig 1</label>
<caption>
<title>Example of collection of headshape points during participant preparation.</title>
</caption>
<graphic mimetype="image" position="float" xlink:href="info:doi/10.1371/journal.pone.0232100.g001" xlink:type="simple"/>
</fig>
<p>Subject preparation and co-registration procedures are important because they influence the quality of electromagnetic source localization [<xref ref-type="bibr" rid="pone.0232100.ref008">8</xref>, <xref ref-type="bibr" rid="pone.0232100.ref009">9</xref>]. Research using MEG has consistently shown that poor co-registration quality can lead to poor source localization [<xref ref-type="bibr" rid="pone.0232100.ref010">10</xref>, <xref ref-type="bibr" rid="pone.0232100.ref011">11</xref>]. When source localization is performed using beamforming, co-registration error greater than approximately 2 mm may yield unacceptably large errors in both source localization [<xref ref-type="bibr" rid="pone.0232100.ref012">12</xref>] and source extent [<xref ref-type="bibr" rid="pone.0232100.ref013">13</xref>]. The same 2 mm threshold appears to apply to source localization using minimum-norm estimates [<xref ref-type="bibr" rid="pone.0232100.ref014">14</xref>], suggesting this threshold as an heuristic for co-registration quality.</p>
<p>During the MEG scan session, the head position coils are energized at known frequencies, which permits the precise measurement of their locations relative to the MEG sensor array. Because at the conclusion of an MEG scan the relative locations of the sensors, coils, anatomical landmarks, and headshape points are known, transforming the MEG data to the participant’s head coordinate space is relatively simple. The key remaining step is to transform the participant’s MRI into the MEG head coordinate space. This transformation is the focus of the MEG-MRI co-registration process.</p>
<p>The manual co-registration process itself is straightforward. A high-resolution 3-D head surface based on the skin-air boundary can be extracted from a T1-weighted MRI using readily-available analysis toolkits such as Freesurfer [<xref ref-type="bibr" rid="pone.0232100.ref015">15</xref>]. Incorporation of this surface into the co-registration process has been shown to improve the quality of the co-registration [<xref ref-type="bibr" rid="pone.0232100.ref010">10</xref>] and is the standard in MNE-python and its predecessor, MNE [<xref ref-type="bibr" rid="pone.0232100.ref016">16</xref>]. In the absence of significant MRI artifacts, the participant’s distinguishing features, including the face and the anatomical landmarks collected during MEG preparation, are clearly visible on this surface. The anatomical landmarks and MEG headshape can be used to co-register the MRI head surface (and therefore the MRI data) to the participant’s head coordinate space. Typically this involves manually identifying the anatomical landmarks on the MRI head surface, using these values to perform an initial transformation, and then applying an iterative closest points algorithm [ICP: <xref ref-type="bibr" rid="pone.0232100.ref017">17</xref>] to assist in refining the transformation until the distance between the MEG headshape and the MRI head surface has been minimized (<xref ref-type="fig" rid="pone.0232100.g002">Fig 2</xref>). This can be accomplished using template MRIs, but MEG data can be localized with higher confidence when the individual participant’s own structural MRI is used for their co-registration. Numerous toolkits are available to assist the analysist in co-registration, including but not limited to MNE-python [<xref ref-type="bibr" rid="pone.0232100.ref018">18</xref>], SPM [<xref ref-type="bibr" rid="pone.0232100.ref019">19</xref>], Fieldtrip [<xref ref-type="bibr" rid="pone.0232100.ref020">20</xref>], BrainStorm [<xref ref-type="bibr" rid="pone.0232100.ref021">21</xref>], and NUTMEG [<xref ref-type="bibr" rid="pone.0232100.ref022">22</xref>].</p>
<fig id="pone.0232100.g002" position="float">
<object-id pub-id-type="doi">10.1371/journal.pone.0232100.g002</object-id>
<label>Fig 2</label>
<caption>
<title>Example headshape points, landmarks, and HPI coils on head surface after co-registration.</title>
</caption>
<graphic mimetype="image" position="float" xlink:href="info:doi/10.1371/journal.pone.0232100.g002" xlink:type="simple"/>
</fig>
<p>Importantly, although both automated and manual approaches to co-registration are available, the consistency of the two approaches has not been systematically evaluated. One common approach to evaluating the consistency of two methods is to compute their inter-method reliability. Inter-method reliability, computationally identical to inter-rater reliability, is a means of assessing the chance-corrected agreement between two different methods. This can be computed using a ratio of the variance of interest divided by the total variance; that is, the intra-class correlation (ICC) [<xref ref-type="bibr" rid="pone.0232100.ref023">23</xref>]. The goal of the present study was to evaluate the inter-method reliability of manual and automated co-registration using the MNE-python toolbox [<xref ref-type="bibr" rid="pone.0232100.ref018">18</xref>].</p>
</sec>
<sec id="sec002" sec-type="materials|methods">
<title>Method</title>
<p>As part of an ongoing study, resting MEG and T1-weighted MRI data were collected from 90 participants (mean age = 35.20 years (SD = 10.04), 42.2% female, 50% Hispanic). MRI data were collected on a Siemens 3T Trio Tim system (Siemens Healthcare, Erlangen, Germany) using a 32-channel head coil. Paper tape was placed across each participant’s forehead to reduce motion. Structural images were collected with magnetization-prepared 180° radiofrequency pulses and rapid gradient-echo sequence (MPRAGE; TE = 1.64, 3.5, 5.36, 7.22, and 9.08 ms; TR = 2.53 s; FA = 7°; number of excitations = 1; slice thickness = 1 mm; FOV = 256 mm; resolution = 256×256). Standard preprocessing was conducted using the Freesurfer image analysis suite [<xref ref-type="bibr" rid="pone.0232100.ref015">15</xref>], which is documented and freely available for download online (<ext-link ext-link-type="uri" xlink:href="http://surfer.nmr.mgh.harvard.edu/" xlink:type="simple">http://surfer.nmr.mgh.harvard.edu/</ext-link>). However, generation of the head surface file used in co-registration relies only upon the existence of a T1 image [<xref ref-type="bibr" rid="pone.0232100.ref024">24</xref>], not on any specific preprocessing package.</p>
<p>MEG data were collected in a magnetically and electrically shielded room (VAC Series Ak3B, Vacuumschmelze GmbH) using an Elekta Neuromag whole-cortex 306-channel MEG array (Elekta Oy, Helsinki, Finland). Before positioning the participant in the MEG, four coils were affixed to the participant’s head—two on the forehead and one behind each ear. Additional positioning data was collected using a head position device (Polhemus Fastrak). Between 83 and 229 points were collected for each subject (median = 143, IQR 122–157). Participants were instructed to keep their eyes open and focused on a fixation cross back-projected onto a screen during the scan. MEG data were sampled at a rate of 1000 Hz, with a bandpass filter of 0.10 to 330 Hz. Head position was monitored continuously throughout the MEG session. Five minutes of raw single-trial data were collected and stored. Data from two MEG measurement sessions were examined.</p>
<p>An experienced technician had previously manually co-registered each MEG scan to its corresponding MRI using MNE [<xref ref-type="bibr" rid="pone.0232100.ref016">16</xref>] following the general steps described in the Introduction. Automated co-registration in MNE-python follows the same general sequence described for manual co-registration. The MNE toolboxes include standard landmark coordinates (nasion, preauricular points) defined on the MNI305 head [<xref ref-type="bibr" rid="pone.0232100.ref025">25</xref>]. The automated co-registration is performed by 1) transforming these coordinates from the MNI305 head to each participant’s MRI coordinate space, 2) performing an initial fit to the MRI head surface using only these landmarks, 3) applying several initial iterations of the iterative closest points (ICP) algorithm, 4) eliminating outlier head points (i.e., those &gt; 5 mm away from the head surface), and 5) applying the ICP algorithm again. The final affine transformation was then saved and the co-registration errors (i.e., the median distance between each MEG headshape point and the nearest point on the MRI head surface) preserved. Errors for manual co-registrations were obtained by applying the affine transformations from the manual co-registration to the MEG headshape and computing the distance between each MEG headshape point and the nearest point on the MRI head surface. Visual inspection was used to assure the quality of the fit. The inter-method reliability of co-registration error for manual and automated co-registration was compared using the intraclass correlation (ICC model 3,1: 23).To evaluate the relationship between participant preparation procedures and co-registration error, we computed the correlation between co-registration error terms and the number of headshape points collected during participant preparation. To assess the comparability of the head transformation matrices produced by each method, we converted each affine transformation matrix to mm of translation in the x, y, and z directions, and degrees of rotation around the x, y, and z axes (i.e., pitch, roll, and yaw), and computed the inter-method reliability for each parameter. Finally, to evaluate whether the automated technique could be applied to anonymized, “de-faced” data, we re-ran the automated co-registration procedure using MRIs that had been de-faced with PyDeface [<xref ref-type="bibr" rid="pone.0232100.ref026">26</xref>].</p>
<p>The methods described above generate a 3D rendering of each participant’s head and face from their structural MRI. While initial studies of such renderings observed relatively low accuracy when matching renderings to facial photographs [<xref ref-type="bibr" rid="pone.0232100.ref027">27</xref>, <xref ref-type="bibr" rid="pone.0232100.ref028">28</xref>], more recent work has indicated that facial recognition software can accurately match renderings to facial photographs with high confidence when sufficient high-quality facial photographs are available [<xref ref-type="bibr" rid="pone.0232100.ref029">29</xref>]. This is a point of ethical concern, as any dataset containing images comparable to facial photographs could result in a loss of privacy to affected research participants if data are shared. This would also lead to a violation of research regulations, such as the HIPAA Privacy Rule in the U.S. [<xref ref-type="bibr" rid="pone.0232100.ref030">30</xref>]. For studies such as ours that are protected by a Certificate of Confidentiality under the U.S. 21<sup>st</sup> Century Cures Act [<xref ref-type="bibr" rid="pone.0232100.ref031">31</xref>], identifying information cannot be shared without participant consent, by force of law. The standard practice is to remove these direct identifiers from datasets [<xref ref-type="bibr" rid="pone.0232100.ref032">32</xref>]. Large U.S. federally-funded studies such as the Human Connectome Project share only de-faced structural MRIs, and for MEG data, also remove the participant’s head shape [<xref ref-type="bibr" rid="pone.0232100.ref033">33</xref>]. As participants in the present study did not consent to data sharing, we have adopted this approach and share only de-identified data, including de-faced structural MRIs and coded co-registration error data for participants, at <ext-link ext-link-type="uri" xlink:href="http://dx.doi.org/10.35092/yhjc.11991546" xlink:type="simple">http://dx.doi.org/10.35092/yhjc.11991546</ext-link>.</p>
</sec>
<sec id="sec003" sec-type="results">
<title>Results</title>
<p>Median co-registration error for manual co-registration was 1.37 mm (IQR 1.17–1.63), and for automatic co-registration 1.58 mm (IQR 1.23–2.05) (<xref ref-type="fig" rid="pone.0232100.g003">Fig 3</xref>). The mean difference in co-registration error between manual and automated co-registration was approximately 0.313 mm (SD 0.555 mm). Co-registration error between the two methods was correlated at <italic>r</italic> = 0.541 (<italic>p</italic> &lt; .001), which corresponds to a Cohen’s <italic>d</italic> of 1.29, a “large” effect size [<xref ref-type="bibr" rid="pone.0232100.ref034">34</xref>]. The association between co-registration error and the number of headshape points was not significant for either the manual (<italic>r</italic> = 0.143, <italic>p</italic> = .058) or the automated (<italic>r</italic> = 0.025, <italic>p</italic> = 0.745) co-registration procedure. The inter-method reliability for the co-registration error between the two co-registration approaches was ICC = 0.472, which is in the “fair” range [<xref ref-type="bibr" rid="pone.0232100.ref035">35</xref>]. After excluding automated co-registration results with unacceptably high error (i.e., &gt; 2.0 mm), inter-method reliability improved only slightly to ICC = 0.491, also in the “fair” range [<xref ref-type="bibr" rid="pone.0232100.ref035">35</xref>]. Inter-method reliability of all translation and rotation parameters was in the good to excellent range (i.e., all ICC &gt; 0.74; see <xref ref-type="table" rid="pone.0232100.t001">Table 1</xref>).</p>
<fig id="pone.0232100.g003" position="float">
<object-id pub-id-type="doi">10.1371/journal.pone.0232100.g003</object-id>
<label>Fig 3</label>
<caption>
<title>Violin plot of co-registration error for manual (left) and automated (right) approaches.</title>
</caption>
<graphic mimetype="image" position="float" xlink:href="info:doi/10.1371/journal.pone.0232100.g003" xlink:type="simple"/>
</fig>
<table-wrap id="pone.0232100.t001" position="float">
<object-id pub-id-type="doi">10.1371/journal.pone.0232100.t001</object-id>
<label>Table 1</label> <caption><title>Descriptive statistics and inter-method reliability results for translation and rotation.</title></caption>
<alternatives>
<graphic id="pone.0232100.t001g" mimetype="image" position="float" xlink:href="info:doi/10.1371/journal.pone.0232100.t001" xlink:type="simple"/>
<table>
<colgroup>
<col align="left" valign="middle"/>
<col align="left" valign="middle"/>
<col align="left" valign="middle"/>
<col align="left" valign="middle"/>
<col align="left" valign="middle"/>
<col align="left" valign="middle"/>
<col align="left" valign="middle"/>
</colgroup>
<thead>
<tr>
<th align="left" rowspan="2"/>
<th align="center" colspan="3">Translation median in mm (IQR)</th>
<th align="center" colspan="3">Rotation median in degrees (IQR)</th>
</tr>
<tr>
<th align="center">x</th>
<th align="center">y</th>
<th align="center">z</th>
<th align="center">Pitch</th>
<th align="center">Roll</th>
<th align="center">Yaw</th>
</tr>
</thead>
<tbody>
<tr>
<td align="left">Manual</td>
<td align="left">-1.861 (-4.604–0.085)</td>
<td align="left">-4.842 (-9.938–1.378)</td>
<td align="left">-72.997 (-78.808–68.277)</td>
<td align="left">15.244 (9.273–19.887)</td>
<td align="left">1.394 (-0.341–3.718)</td>
<td align="left">-0.955 (-2.496–0.886)</td>
</tr>
<tr>
<td align="left">Automated</td>
<td align="left">-1.549 (-3.543–0.514)</td>
<td align="left">-5.962 (-10.424–2.062)</td>
<td align="left">-67.514 (-71.163–63.607)</td>
<td align="left">13.260 (8.011–18.450)</td>
<td align="left">1.026 (-0.668–2.687)</td>
<td align="left">-0.265 (-2.135–1.276)</td>
</tr>
<tr>
<td align="left">ICC</td>
<td align="left">0.903</td>
<td align="left">0.922</td>
<td align="left">0.833</td>
<td align="left">0.874</td>
<td align="left">0.748</td>
<td align="left">0.896</td>
</tr>
</tbody>
</table>
</alternatives>
<table-wrap-foot>
<fn id="t001fn001"><p>ICC = Intra-class correlation (model 3,1).</p></fn>
</table-wrap-foot>
</table-wrap>
<p>Median co-registration error for automatic co-registration with de-faced MRIs was 2.01 mm (IQR 1.71–2.32). The difference in co-registration error between manual co-registration with original MRIs and automated co-registration with de-faced MRIs was approximately 0.619 mm (SD 0.577 mm). The inter-method reliability for manual co-registration with original MRIs and automated co-registration with de-faced MRIs was ICC = 0.045, which is in the “poor” range [<xref ref-type="bibr" rid="pone.0232100.ref014">14</xref>].</p>
</sec>
<sec id="sec004" sec-type="conclusions">
<title>Discussion</title>
<p>In our data, both manual and automated co-registration yielded generally acceptable results. The co-registration error obtained for both processes in the present study is also consistent with that of other studies. For instance, a study using bite bars to reduce motion found a mean co-registration error of 1.16 mm [<xref ref-type="bibr" rid="pone.0232100.ref005">5</xref>], while a study using a 3D scanner found mean error of 2.2 mm [<xref ref-type="bibr" rid="pone.0232100.ref007">7</xref>], and one using a 3D camera (Kinect) observed a mean error of 1.62 mm [<xref ref-type="bibr" rid="pone.0232100.ref006">6</xref>]. Despite the ready availability of co-registration error metrics, reporting of these metrics in MEG studies has not yet become standard practice [<xref ref-type="bibr" rid="pone.0232100.ref036">36</xref>, <xref ref-type="bibr" rid="pone.0232100.ref037">37</xref>].</p>
<p>The inter-method reliability results, in the “fair” range for co-registration error and the “good” to “excellent” range for translation and rotation parameters, suggests that the outputs of the manual and automated co-registration processes applied in this study are similar. That is, despite the extensive training and time requirements of manual co-registration, the results of the manual and automated co-registration procedures were in agreement, for both co-registration error and for the translations and rotations that were applied to align the MEG headshape points and MRI head surface. However, based on the results of the present study, automated co-registration using de-faced MRIs should be viewed with some caution.</p>
<p>It is worth noting that the MRI scans included in the present study appear to have been relatively artifact-free. Data from participants with common sources of susceptibility artifact such as braces, permanent retainers, other dental work, and certain hair products [<xref ref-type="bibr" rid="pone.0232100.ref038">38</xref>] would likely result in distortions of the head surface generated from the T1-weighted MRI, requiring greater attention and the potential for manual intervention during co-registration.</p>
</sec>
<sec id="sec005" sec-type="conclusions">
<title>Conclusion</title>
<p>Until devices capable of collecting simultaneous MRI and MEG data become commercially available [<xref ref-type="bibr" rid="pone.0232100.ref039">39</xref>], co-registration will remain a limiting factor in the localization accuracy of MEG data [<xref ref-type="bibr" rid="pone.0232100.ref010">10</xref>–<xref ref-type="bibr" rid="pone.0232100.ref014">14</xref>]. Because reporting of co-registration error is not yet a best practice for MEG [<xref ref-type="bibr" rid="pone.0232100.ref036">36</xref>], adoption has been slow. The implementation of procedures to estimate co-registration error in analysis packages such as MNE-python [<xref ref-type="bibr" rid="pone.0232100.ref018">18</xref>] may help to accelerate this. Our results suggest that in many cases a simple automated processes performed using freely-available and open-source software can co-register MEG and MRI data with results similar to those achieved by manual co-registration, avoiding the time and training requirements of manual procedures.</p>
<sec id="sec006">
<title>Ethical approval and informed consent statement</title>
<p>All study protocols were approved by the University of New Mexico Institutional Review Board (<ext-link ext-link-type="uri" xlink:href="http://irb.unm.edu/" xlink:type="simple">http://irb.unm.edu</ext-link>). All procedures were carried out in accordance with the relevant guidelines and regulations. Documented informed consent was obtained from all participants. Documented consent for the publication of the photograph presented in <xref ref-type="fig" rid="pone.0232100.g001">Fig 1</xref> and the rendering presented in <xref ref-type="fig" rid="pone.0232100.g002">Fig 2</xref> was obtained from the individual pictured, who was not a participant in this research study.</p>
</sec>
</sec>
</body>
<back>
<ref-list>
<title>References</title>
<ref id="pone.0232100.ref001"><label>1</label><mixed-citation publication-type="journal" xlink:type="simple"><name name-style="western"><surname>Lü</surname> <given-names>Z-L</given-names></name>, <name name-style="western"><surname>Williamson</surname> <given-names>SJ</given-names></name>. <article-title>Spatial extent of coherent sensory-evoked cortical activity</article-title>. <source>Exp Brain Res</source>. <year>1991</year>;<volume>84</volume>(<issue>2</issue>):<fpage>411</fpage>–<lpage>6</lpage>. <comment>doi: <ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1007/bf00231463" xlink:type="simple">10.1007/bf00231463</ext-link></comment> <object-id pub-id-type="pmid">2065748</object-id></mixed-citation></ref>
<ref id="pone.0232100.ref002"><label>2</label><mixed-citation publication-type="journal" xlink:type="simple"><name name-style="western"><surname>Bagić</surname> <given-names>AI</given-names></name>. <article-title>Disparities in clinical magnetoencephalography practice in the United States: a survey-based appraisal</article-title>. <source>J Clin Neurophysiol Off Publ Am Electroencephalogr Soc</source>. <year>2011</year> <month>Aug</month>;<volume>28</volume>(<issue>4</issue>):<fpage>341</fpage>–<lpage>7</lpage>.</mixed-citation></ref>
<ref id="pone.0232100.ref003"><label>3</label><mixed-citation publication-type="journal" xlink:type="simple"><name name-style="western"><surname>Hämäläinen</surname> <given-names>M</given-names></name>. <article-title>Anatomical correlates for magnetoencephalography: integration with magnetic resonance images</article-title>. <source>Clin Phys Physiol Meas</source>. <year>1991</year> <month>Jan</month>;<volume>12</volume>(<issue>A</issue>):<fpage>29</fpage>–<lpage>32</lpage>.</mixed-citation></ref>
<ref id="pone.0232100.ref004"><label>4</label><mixed-citation publication-type="other" xlink:type="simple">CoordinateSystems—Free Surfer Wiki [Internet]. [cited 2019 Dec 18]. Available from: <ext-link ext-link-type="uri" xlink:href="https://surfer.nmr.mgh.harvard.edu/fswiki/CoordinateSystems" xlink:type="simple">https://surfer.nmr.mgh.harvard.edu/fswiki/CoordinateSystems</ext-link></mixed-citation></ref>
<ref id="pone.0232100.ref005"><label>5</label><mixed-citation publication-type="journal" xlink:type="simple"><name name-style="western"><surname>Adjamian</surname> <given-names>P</given-names></name>, <name name-style="western"><surname>Barnes</surname> <given-names>GR</given-names></name>, <name name-style="western"><surname>Hillebrand</surname> <given-names>A</given-names></name>, <name name-style="western"><surname>Holliday</surname> <given-names>IE</given-names></name>, <name name-style="western"><surname>Singh</surname> <given-names>KD</given-names></name>, <name name-style="western"><surname>Furlong</surname> <given-names>PL</given-names></name>, <etal>et al</etal>. <article-title>Co-registration of magnetoencephalography with magnetic resonance imaging using bite-bar-based fiducials and surface-matching</article-title>. <source>Clin Neurophysiol</source>. <year>2004</year> <month>Mar</month>;<volume>115</volume>(<issue>3</issue>):<fpage>691</fpage>–<lpage>8</lpage>. <comment>doi: <ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1016/j.clinph.2003.10.023" xlink:type="simple">10.1016/j.clinph.2003.10.023</ext-link></comment> <object-id pub-id-type="pmid">15036065</object-id></mixed-citation></ref>
<ref id="pone.0232100.ref006"><label>6</label><mixed-citation publication-type="journal" xlink:type="simple"><name name-style="western"><surname>Vema Krishna Murthy</surname> <given-names>S</given-names></name>, <name name-style="western"><surname>MacLellan</surname> <given-names>M</given-names></name>, <name name-style="western"><surname>Beyea</surname> <given-names>S</given-names></name>, <name name-style="western"><surname>Bardouille</surname> <given-names>T</given-names></name>. <article-title>Faster and improved 3-D head digitization in MEG using Kinect</article-title>. <source>Front Neurosci</source> [Internet]. <year>2014</year> <month>Oct</month> <day>28</day> [cited 2015 Aug 21];8. Available from: <ext-link ext-link-type="uri" xlink:href="http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4211394/" xlink:type="simple">http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4211394/</ext-link></mixed-citation></ref>
<ref id="pone.0232100.ref007"><label>7</label><mixed-citation publication-type="journal" xlink:type="simple"><name name-style="western"><surname>Bardouille</surname> <given-names>T</given-names></name>, <name name-style="western"><surname>Krishnamurthy</surname> <given-names>SV</given-names></name>, <name name-style="western"><surname>Ghosh Hajra</surname> <given-names>S</given-names></name>, <name name-style="western"><surname>D’Arcy</surname> <given-names>RCN</given-names></name>. <article-title>Improved Localization Accuracy in Magnetic Source Imaging Using a 3-D Laser Scanner</article-title>. <source>IEEE Trans Biomed Eng</source>. <year>2012</year> <month>Dec</month>;<volume>59</volume>(<issue>12</issue>):<fpage>3491</fpage>–<lpage>7</lpage>. <comment>doi: <ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1109/TBME.2012.2220356" xlink:type="simple">10.1109/TBME.2012.2220356</ext-link></comment> <object-id pub-id-type="pmid">23033325</object-id></mixed-citation></ref>
<ref id="pone.0232100.ref008"><label>8</label><mixed-citation publication-type="journal" xlink:type="simple"><name name-style="western"><surname>Dalal</surname> <given-names>SS</given-names></name>, <name name-style="western"><surname>Rampp</surname> <given-names>S</given-names></name>, <name name-style="western"><surname>Willomitzer</surname> <given-names>F</given-names></name>, <name name-style="western"><surname>Ettl</surname> <given-names>S</given-names></name>. <article-title>Consequences of EEG electrode position error on ultimate beamformer source reconstruction performance</article-title>. <source>Front Neurosci</source> [Internet]. <year>2014</year> [cited 2019 Oct 9];<volume>8</volume>. Available from: <ext-link ext-link-type="uri" xlink:href="https://www.frontiersin.org/articles/10.3389/fnins.2014.00042/full" xlink:type="simple">https://www.frontiersin.org/articles/10.3389/fnins.2014.00042/full</ext-link></mixed-citation></ref>
<ref id="pone.0232100.ref009"><label>9</label><mixed-citation publication-type="journal" xlink:type="simple"><name name-style="western"><surname>Acar</surname> <given-names>ZA</given-names></name>, <name name-style="western"><surname>Makeig</surname> <given-names>S</given-names></name>. <article-title>Effects of Forward Model Errors on EEG Source Localization</article-title>. <source>Brain Topogr</source>. <year>2013</year> <month>Jan</month> <day>26</day>;<volume>26</volume>(<issue>3</issue>):<fpage>378</fpage>–<lpage>96</lpage>. <comment>doi: <ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1007/s10548-012-0274-6" xlink:type="simple">10.1007/s10548-012-0274-6</ext-link></comment> <object-id pub-id-type="pmid">23355112</object-id></mixed-citation></ref>
<ref id="pone.0232100.ref010"><label>10</label><mixed-citation publication-type="journal" xlink:type="simple"><name name-style="western"><surname>Whalen</surname> <given-names>C</given-names></name>, <name name-style="western"><surname>Maclin</surname> <given-names>EL</given-names></name>, <name name-style="western"><surname>Fabiani</surname> <given-names>M</given-names></name>, <name name-style="western"><surname>Gratton</surname> <given-names>G</given-names></name>. <article-title>Validation of a method for coregistering scalp recording locations with 3D structural MR images</article-title>. <source>Hum Brain Mapp</source>. <year>2008</year>;<volume>29</volume>(<issue>11</issue>):<fpage>1288</fpage>–<lpage>301</lpage>. <comment>doi: <ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1002/hbm.20465" xlink:type="simple">10.1002/hbm.20465</ext-link></comment> <object-id pub-id-type="pmid">17894391</object-id></mixed-citation></ref>
<ref id="pone.0232100.ref011"><label>11</label><mixed-citation publication-type="journal" xlink:type="simple"><name name-style="western"><surname>Troebinger</surname> <given-names>L</given-names></name>, <name name-style="western"><surname>López</surname> <given-names>JD</given-names></name>, <name name-style="western"><surname>Lutti</surname> <given-names>A</given-names></name>, <name name-style="western"><surname>Bradbury</surname> <given-names>D</given-names></name>, <name name-style="western"><surname>Bestmann</surname> <given-names>S</given-names></name>, <name name-style="western"><surname>Barnes</surname> <given-names>G</given-names></name>. <article-title>High precision anatomy for MEG</article-title>. <source>NeuroImage</source>. <year>2014</year> <month>Feb</month> <day>1</day>;<volume>86</volume>:<fpage>583</fpage>–<lpage>91</lpage>. <comment>doi: <ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1016/j.neuroimage.2013.07.065" xlink:type="simple">10.1016/j.neuroimage.2013.07.065</ext-link></comment> <object-id pub-id-type="pmid">23911673</object-id></mixed-citation></ref>
<ref id="pone.0232100.ref012"><label>12</label><mixed-citation publication-type="journal" xlink:type="simple"><name name-style="western"><surname>Hillebrand</surname> <given-names>A</given-names></name>, <name name-style="western"><surname>Barnes</surname> <given-names>GR</given-names></name>. <article-title>The use of anatomical constraints with MEG beamformers</article-title>. <source>NeuroImage</source>. <year>2003</year> <month>Dec</month>;<volume>20</volume>(<issue>4</issue>):<fpage>2302</fpage>–<lpage>13</lpage>. <comment>doi: <ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1016/j.neuroimage.2003.07.031" xlink:type="simple">10.1016/j.neuroimage.2003.07.031</ext-link></comment> <object-id pub-id-type="pmid">14683731</object-id></mixed-citation></ref>
<ref id="pone.0232100.ref013"><label>13</label><mixed-citation publication-type="journal" xlink:type="simple"><name name-style="western"><surname>Hillebrand</surname> <given-names>A</given-names></name>, <name name-style="western"><surname>Barnes</surname> <given-names>GR</given-names></name>. <article-title>Practical constraints on estimation of source extent with MEG beamformers</article-title>. <source>NeuroImage</source>. <year>2011</year> <month>Feb</month> <day>14</day>;<volume>54</volume>(<issue>4</issue>):<fpage>2732</fpage>–<lpage>40</lpage>. <comment>doi: <ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1016/j.neuroimage.2010.10.036" xlink:type="simple">10.1016/j.neuroimage.2010.10.036</ext-link></comment> <object-id pub-id-type="pmid">20969964</object-id></mixed-citation></ref>
<ref id="pone.0232100.ref014"><label>14</label><mixed-citation publication-type="journal" xlink:type="simple"><name name-style="western"><surname>Chang</surname> <given-names>W-T</given-names></name>, <name name-style="western"><surname>Ahlfors</surname> <given-names>SP</given-names></name>, <name name-style="western"><surname>Lin</surname> <given-names>F-H</given-names></name>. <article-title>Sparse current source estimation for MEG using loose orientation constraints</article-title>. <source>Hum Brain Mapp</source>. <year>2013</year>;<volume>34</volume>(<issue>9</issue>):<fpage>2190</fpage>–<lpage>201</lpage>. <comment>doi: <ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1002/hbm.22057" xlink:type="simple">10.1002/hbm.22057</ext-link></comment> <object-id pub-id-type="pmid">22438263</object-id></mixed-citation></ref>
<ref id="pone.0232100.ref015"><label>15</label><mixed-citation publication-type="journal" xlink:type="simple"><name name-style="western"><surname>Fischl</surname> <given-names>B</given-names></name>. <article-title>FreeSurfer</article-title>. <source>NeuroImage</source>. <year>2012</year>;<volume>62</volume>(<issue>2</issue>):<fpage>774</fpage>–<lpage>81</lpage>. <comment>doi: <ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1016/j.neuroimage.2012.01.021" xlink:type="simple">10.1016/j.neuroimage.2012.01.021</ext-link></comment> <object-id pub-id-type="pmid">22248573</object-id></mixed-citation></ref>
<ref id="pone.0232100.ref016"><label>16</label><mixed-citation publication-type="other" xlink:type="simple">Hämäläinen M. MNE [Internet]. 2001. Available from: <ext-link ext-link-type="uri" xlink:href="http://www.nmr.mgh.harvard.edu/martinos/userInfo/data/MNE_register/index.php" xlink:type="simple">http://www.nmr.mgh.harvard.edu/martinos/userInfo/data/MNE_register/index.php</ext-link></mixed-citation></ref>
<ref id="pone.0232100.ref017"><label>17</label><mixed-citation publication-type="journal" xlink:type="simple"><name name-style="western"><surname>Besl</surname> <given-names>PJ</given-names></name>, <name name-style="western"><surname>McKay</surname> <given-names>HD</given-names></name>. <article-title>A method for registration of 3-D shapes</article-title>. <source>IEEE Trans Pattern Anal Mach Intell</source>. <year>1992</year> <month>Feb</month>;<volume>14</volume>(<issue>2</issue>):<fpage>239</fpage>–<lpage>56</lpage>.</mixed-citation></ref>
<ref id="pone.0232100.ref018"><label>18</label><mixed-citation publication-type="journal" xlink:type="simple"><name name-style="western"><surname>Gramfort</surname> <given-names>A</given-names></name>, <name name-style="western"><surname>Luessi</surname> <given-names>M</given-names></name>, <name name-style="western"><surname>Larson</surname> <given-names>E</given-names></name>, <name name-style="western"><surname>Engemann</surname> <given-names>D</given-names></name>, <name name-style="western"><surname>Strohmeier</surname> <given-names>D</given-names></name>, <name name-style="western"><surname>Brodbeck</surname> <given-names>C</given-names></name>, <etal>et al</etal>. <article-title>MNE software for processing MEG and EEG data</article-title>. <source>NeuroImage</source>. <year>2014</year>;<volume>86</volume>:<fpage>446</fpage>–<lpage>60</lpage>. <comment>doi: <ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1016/j.neuroimage.2013.10.027" xlink:type="simple">10.1016/j.neuroimage.2013.10.027</ext-link></comment> <object-id pub-id-type="pmid">24161808</object-id></mixed-citation></ref>
<ref id="pone.0232100.ref019"><label>19</label><mixed-citation publication-type="book" xlink:type="simple"><name name-style="western"><surname>FRISTON</surname> <given-names>K</given-names></name>, <name name-style="western"><surname>ASHBURNER</surname> <given-names>J</given-names></name>, <name name-style="western"><surname>KIEBEL</surname> <given-names>S</given-names></name>, <name name-style="western"><surname>NICHOLS</surname> <given-names>T</given-names></name>, <name name-style="western"><surname>PENNY</surname> <given-names>W</given-names></name>, editors. <source>Statistical Parametric Mapping: The Analysis of Functional Brain Images</source> [Internet]. <publisher-loc>London</publisher-loc>: <publisher-name>Academic Press</publisher-name>; <year>2007</year>. Available from: <ext-link ext-link-type="uri" xlink:href="http://www.sciencedirect.com/science/article/pii/B9780123725608500000" xlink:type="simple">http://www.sciencedirect.com/science/article/pii/B9780123725608500000</ext-link></mixed-citation></ref>
<ref id="pone.0232100.ref020"><label>20</label><mixed-citation publication-type="journal" xlink:type="simple"><name name-style="western"><surname>Oostenveld</surname> <given-names>R</given-names></name>, <name name-style="western"><surname>Fries</surname> <given-names>P</given-names></name>, <name name-style="western"><surname>Maris</surname> <given-names>E</given-names></name>, <name name-style="western"><surname>Schoffelen</surname> <given-names>J-M</given-names></name>. <article-title>FieldTrip: Open Source Software for Advanced Analysis of MEG, EEG, and Invasive Electrophysiological Data</article-title>. <source>Comput Intell Neurosci</source>. <year>2011</year>;<volume>2011</volume>:<fpage>1</fpage>–<lpage>9</lpage>. <comment>doi: <ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1155/2011/720971" xlink:type="simple">10.1155/2011/720971</ext-link></comment></mixed-citation></ref>
<ref id="pone.0232100.ref021"><label>21</label><mixed-citation publication-type="journal" xlink:type="simple"><name name-style="western"><surname>Tadel</surname> <given-names>F</given-names></name>, <name name-style="western"><surname>Baillet</surname> <given-names>S</given-names></name>, <name name-style="western"><surname>Mosher</surname> <given-names>JC</given-names></name>, <name name-style="western"><surname>Pantazis</surname> <given-names>D</given-names></name>, <name name-style="western"><surname>Leahy</surname> <given-names>RM</given-names></name>. <article-title>Brainstorm: A User-Friendly Application for MEG/EEG Analysis</article-title>. <source>Comput Intell Neurosci</source>. <year>2011</year>;<volume>2011</volume>:<fpage>1</fpage>–<lpage>13</lpage>. <comment>doi: <ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1155/2011/720971" xlink:type="simple">10.1155/2011/720971</ext-link></comment></mixed-citation></ref>
<ref id="pone.0232100.ref022"><label>22</label><mixed-citation publication-type="journal" xlink:type="simple"><name name-style="western"><surname>Dalal</surname> <given-names>S</given-names></name>, <name name-style="western"><surname>Zumer</surname> <given-names>J</given-names></name>, <name name-style="western"><surname>Agrawal</surname> <given-names>V</given-names></name>, <name name-style="western"><surname>Hild</surname> <given-names>K</given-names></name>, <name name-style="western"><surname>Sekihara</surname> <given-names>K</given-names></name>, <name name-style="western"><surname>Nagarajan</surname> <given-names>S</given-names></name>. <article-title>NUTMEG: A Neuromagnetic Source Reconstruction Toolbox</article-title>. <source>Neurol Clin Neurophysiol NCN</source>. <year>2004</year> <month>Nov</month> <day>30</day>;<volume>2004</volume>:<fpage>52</fpage>. <object-id pub-id-type="pmid">16012626</object-id></mixed-citation></ref>
<ref id="pone.0232100.ref023"><label>23</label><mixed-citation publication-type="journal" xlink:type="simple"><name name-style="western"><surname>Shrout</surname> <given-names>P</given-names></name>, <name name-style="western"><surname>Fleiss</surname> <given-names>JL</given-names></name>. <article-title>Intraclass correlations: Uses in assessing rater reliability</article-title>. <source>Psychol Bull</source>. <year>1979</year>;<volume>86</volume>:<fpage>420</fpage>–<lpage>8</lpage>. <comment>doi: <ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1037//0033-2909.86.2.420" xlink:type="simple">10.1037//0033-2909.86.2.420</ext-link></comment> <object-id pub-id-type="pmid">18839484</object-id></mixed-citation></ref>
<ref id="pone.0232100.ref024"><label>24</label><mixed-citation publication-type="other" xlink:type="simple">Greve DN, Kaufman, Zeke. Freesurfer mkheadsurf [Internet]. FreeSurfer; 2016 [cited 2019 Nov 21]. Available from: <ext-link ext-link-type="uri" xlink:href="https://github.com/freesurfer/freesurfer/blob/stable6/scripts/mkheadsurf" xlink:type="simple">https://github.com/freesurfer/freesurfer/blob/stable6/scripts/mkheadsurf</ext-link></mixed-citation></ref>
<ref id="pone.0232100.ref025"><label>25</label><mixed-citation publication-type="other" xlink:type="simple">Evans AC, Collins DL, Mills SR, Brown ED, Kelly RL, Peters TM. 3D statistical neuroanatomical models from 305 MRI volumes. In: 1993 IEEE Conference Record Nuclear Science Symposium and Medical Imaging Conference. 1993. p. 1813–7 vol.3.</mixed-citation></ref>
<ref id="pone.0232100.ref026"><label>26</label><mixed-citation publication-type="other" xlink:type="simple">PyDeface [Internet]. poldracklab; 2019 [cited 2019 Dec 15]. Available from: <ext-link ext-link-type="uri" xlink:href="https://github.com/poldracklab/pydeface" xlink:type="simple">https://github.com/poldracklab/pydeface</ext-link></mixed-citation></ref>
<ref id="pone.0232100.ref027"><label>27</label><mixed-citation publication-type="journal" xlink:type="simple"><name name-style="western"><surname>Prior</surname> <given-names>FW</given-names></name>, <name name-style="western"><surname>Brunsden</surname> <given-names>B</given-names></name>, <name name-style="western"><surname>Hildebolt</surname> <given-names>C</given-names></name>, <name name-style="western"><surname>Nolan</surname> <given-names>TS</given-names></name>, <name name-style="western"><surname>Pringle</surname> <given-names>M</given-names></name>, <name name-style="western"><surname>Vaishnavi</surname> <given-names>SN</given-names></name>, <etal>et al</etal>. <article-title>Facial Recognition From Volume-Rendered Magnetic Resonance Imaging Data</article-title>. <source>IEEE Trans Inf Technol Biomed</source>. <year>2009</year> <month>Jan</month>;<volume>13</volume>(<issue>1</issue>):<fpage>5</fpage>–<lpage>9</lpage>. <comment>doi: <ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1109/TITB.2008.2003335" xlink:type="simple">10.1109/TITB.2008.2003335</ext-link></comment> <object-id pub-id-type="pmid">19129018</object-id></mixed-citation></ref>
<ref id="pone.0232100.ref028"><label>28</label><mixed-citation publication-type="journal" xlink:type="simple"><name name-style="western"><surname>Mazura</surname> <given-names>JC</given-names></name>, <name name-style="western"><surname>Juluru</surname> <given-names>K</given-names></name>, <name name-style="western"><surname>Chen</surname> <given-names>JJ</given-names></name>, <name name-style="western"><surname>Morgan</surname> <given-names>TA</given-names></name>, <name name-style="western"><surname>John</surname> <given-names>M</given-names></name>, <name name-style="western"><surname>Siegel</surname> <given-names>EL</given-names></name>. <article-title>Facial Recognition Software Success Rates for the Identification of 3D Surface Reconstructed Facial Images: Implications for Patient Privacy and Security</article-title>. <source>J Digit Imaging</source>. <year>2012</year> <month>Jun</month> <day>1</day>;<volume>25</volume>(<issue>3</issue>):<fpage>347</fpage>–<lpage>51</lpage>. <comment>doi: <ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1007/s10278-011-9429-3" xlink:type="simple">10.1007/s10278-011-9429-3</ext-link></comment> <object-id pub-id-type="pmid">22065158</object-id></mixed-citation></ref>
<ref id="pone.0232100.ref029"><label>29</label><mixed-citation publication-type="journal" xlink:type="simple"><name name-style="western"><surname>Schwarz</surname> <given-names>CG</given-names></name>, <name name-style="western"><surname>Kremers</surname> <given-names>WK</given-names></name>, <name name-style="western"><surname>Therneau</surname> <given-names>TM</given-names></name>, <name name-style="western"><surname>Sharp</surname> <given-names>RR</given-names></name>, <name name-style="western"><surname>Gunter</surname> <given-names>JL</given-names></name>, <name name-style="western"><surname>Vemuri</surname> <given-names>P</given-names></name>, <etal>et al</etal>. <article-title>Identification of Anonymous MRI Research Participants with Face-Recognition Software</article-title>. <source>N Engl J Med</source>. <year>2019</year> <month>Oct</month> <day>24</day>;<volume>381</volume>(<issue>17</issue>):<fpage>1684</fpage>–<lpage>6</lpage>. <comment>doi: <ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1056/NEJMc1908881" xlink:type="simple">10.1056/NEJMc1908881</ext-link></comment> <object-id pub-id-type="pmid">31644852</object-id></mixed-citation></ref>
<ref id="pone.0232100.ref030"><label>30</label><mixed-citation publication-type="other" xlink:type="simple">U.S. Department of Health &amp; Human Services, Office for Civil Rights. Summary of the HIPAA Privacy Rule [Internet]. Available from: <ext-link ext-link-type="uri" xlink:href="https://www.hhs.gov/hipaa/for-professionals/privacy/laws-regulations/index.html" xlink:type="simple">https://www.hhs.gov/hipaa/for-professionals/privacy/laws-regulations/index.html</ext-link></mixed-citation></ref>
<ref id="pone.0232100.ref031"><label>31</label><mixed-citation publication-type="other" xlink:type="simple">An act to accelerate the discovery, development, and delivery of 21st century cures, and for other purposes. Public Law 114–255 Dec 13, 2016. Available from: <ext-link ext-link-type="uri" xlink:href="https://www.govinfo.gov/app/details/PLAW-114publ255" xlink:type="simple">https://www.govinfo.gov/app/details/PLAW-114publ255</ext-link></mixed-citation></ref>
<ref id="pone.0232100.ref032"><label>32</label><mixed-citation publication-type="journal" xlink:type="simple"><name name-style="western"><surname>Hrynaszkiewicz</surname> <given-names>I</given-names></name>, <name name-style="western"><surname>Norton</surname> <given-names>ML</given-names></name>, <name name-style="western"><surname>Vickers</surname> <given-names>AJ</given-names></name>, <name name-style="western"><surname>Altman</surname> <given-names>DG</given-names></name>. <article-title>Preparing raw clinical data for publication: guidance for journal editors, authors, and peer reviewers</article-title>. <source>BMJ</source>. <year>2010</year> <month>Jan</month> <day>29</day>; <volume>340</volume>. Available from: <ext-link ext-link-type="uri" xlink:href="https://www.bmj.com/content/340/bmj.c181" xlink:type="simple">https://www.bmj.com/content/340/bmj.c181</ext-link></mixed-citation></ref>
<ref id="pone.0232100.ref033"><label>33</label><mixed-citation publication-type="journal" xlink:type="simple"><name name-style="western"><surname>Van Essen</surname> <given-names>DC</given-names></name>, <name name-style="western"><surname>Smith</surname> <given-names>SM</given-names></name>, <name name-style="western"><surname>Barch</surname> <given-names>DM</given-names></name>, <name name-style="western"><surname>Behrens</surname> <given-names>TEJ</given-names></name>, <name name-style="western"><surname>Yacoub</surname> <given-names>E</given-names></name>, <name name-style="western"><surname>Ugurbil</surname> <given-names>K</given-names></name>. <article-title>The WU-Minn Human Connectome Project: An overview</article-title>. <source>NeuroImage</source>. <year>2013</year> <month>Oct</month> <day>15</day>;<volume>80</volume>:<fpage>62</fpage>–<lpage>79</lpage>. <comment>doi: <ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1016/j.neuroimage.2013.05.041" xlink:type="simple">10.1016/j.neuroimage.2013.05.041</ext-link></comment> <object-id pub-id-type="pmid">23684880</object-id></mixed-citation></ref>
<ref id="pone.0232100.ref034"><label>34</label><mixed-citation publication-type="book" xlink:type="simple"><name name-style="western"><surname>Cohen</surname> <given-names>J</given-names></name>. <source>Statistical Power Analysis for the Behavioral Sciences</source>. <edition>2nd</edition> ed. <publisher-name>Routledge Academic</publisher-name>; <year>1988</year>.</mixed-citation></ref>
<ref id="pone.0232100.ref035"><label>35</label><mixed-citation publication-type="journal" xlink:type="simple"><name name-style="western"><surname>Cicchetti</surname> <given-names>DV</given-names></name>, <name name-style="western"><surname>Sparrow</surname> <given-names>SA</given-names></name>. <article-title>Developing criteria for establishing interrater reliability of specific items: Applications to assessment of adaptive behavior</article-title>. <source>Am J Ment Defic</source>. <year>1981</year>;<volume>86</volume>:<fpage>127</fpage>–<lpage>37</lpage>. <object-id pub-id-type="pmid">7315877</object-id></mixed-citation></ref>
<ref id="pone.0232100.ref036"><label>36</label><mixed-citation publication-type="journal" xlink:type="simple"><name name-style="western"><surname>Gross</surname> <given-names>J</given-names></name>, <name name-style="western"><surname>Baillet</surname> <given-names>S</given-names></name>, <name name-style="western"><surname>Barnes</surname> <given-names>GR</given-names></name>, <name name-style="western"><surname>Henson</surname> <given-names>RN</given-names></name>, <name name-style="western"><surname>Hillebrand</surname> <given-names>A</given-names></name>, <name name-style="western"><surname>Jensen</surname> <given-names>O</given-names></name>, <etal>et al</etal>. <article-title>Good practice for conducting and reporting MEG research</article-title>. <source>NeuroImage</source>. <year>2013</year> <month>Jan</month> <day>15</day>;<volume>65</volume>:<fpage>349</fpage>–<lpage>63</lpage>. <comment>doi: <ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1016/j.neuroimage.2012.10.001" xlink:type="simple">10.1016/j.neuroimage.2012.10.001</ext-link></comment> <object-id pub-id-type="pmid">23046981</object-id></mixed-citation></ref>
<ref id="pone.0232100.ref037"><label>37</label><mixed-citation publication-type="journal" xlink:type="simple"><name name-style="western"><surname>Keil</surname> <given-names>A</given-names></name>, <name name-style="western"><surname>Debener</surname> <given-names>S</given-names></name>, <name name-style="western"><surname>Gratton</surname> <given-names>G</given-names></name>, <name name-style="western"><surname>Junghöfer</surname> <given-names>M</given-names></name>, <name name-style="western"><surname>Kappenman</surname> <given-names>ES</given-names></name>, <name name-style="western"><surname>Luck</surname> <given-names>SJ</given-names></name>, <etal>et al</etal>. <article-title>Committee report: Publication guidelines and recommendations for studies using electroencephalography and magnetoencephalography</article-title>. <source>Psychophysiology</source>. <year>2014</year> <month>Jan</month> <day>1</day>;<volume>51</volume>(<issue>1</issue>):<fpage>1</fpage>–<lpage>21</lpage>. <comment>doi: <ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1111/psyp.12147" xlink:type="simple">10.1111/psyp.12147</ext-link></comment> <object-id pub-id-type="pmid">24147581</object-id></mixed-citation></ref>
<ref id="pone.0232100.ref038"><label>38</label><mixed-citation publication-type="journal" xlink:type="simple"><name name-style="western"><surname>Chenji</surname> <given-names>S</given-names></name>, <name name-style="western"><surname>Wilman</surname> <given-names>AH</given-names></name>, <name name-style="western"><surname>Mah</surname> <given-names>D</given-names></name>, <name name-style="western"><surname>Seres</surname> <given-names>P</given-names></name>, <name name-style="western"><surname>Genge</surname> <given-names>A</given-names></name>, <name name-style="western"><surname>Kalra</surname> <given-names>S</given-names></name>. <article-title>Hair product artifact in magnetic resonance imaging</article-title>. <source>Magn Reson Imaging</source>. <year>2017</year> <month>Jan</month> <day>1</day>;<volume>35</volume>:<fpage>1</fpage>–<lpage>3</lpage>. <comment>doi: <ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1016/j.mri.2016.08.023" xlink:type="simple">10.1016/j.mri.2016.08.023</ext-link></comment> <object-id pub-id-type="pmid">27590880</object-id></mixed-citation></ref>
<ref id="pone.0232100.ref039"><label>39</label><mixed-citation publication-type="journal" xlink:type="simple"><name name-style="western"><surname>Vesanen</surname> <given-names>PT</given-names></name>, <name name-style="western"><surname>Nieminen</surname> <given-names>JO</given-names></name>, <name name-style="western"><surname>Zevenhoven</surname> <given-names>KCJ</given-names></name>, <name name-style="western"><surname>Dabek</surname> <given-names>J</given-names></name>, <name name-style="western"><surname>Parkkonen</surname> <given-names>LT</given-names></name>, <name name-style="western"><surname>Zhdanov</surname> <given-names>AV</given-names></name>, <etal>et al</etal>. <article-title>Hybrid ultra-low-field MRI and magnetoencephalography system based on a commercial whole-head neuromagnetometer</article-title>. <source>Magn Reson Med</source>. <year>2013</year>;<volume>69</volume>(<issue>6</issue>):<fpage>1795</fpage>–<lpage>804</lpage>. <comment>doi: <ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1002/mrm.24413" xlink:type="simple">10.1002/mrm.24413</ext-link></comment> <object-id pub-id-type="pmid">22807201</object-id></mixed-citation></ref>
</ref-list>
</back>
</article>