<?xml version="1.0" encoding="utf-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD JATS (Z39.96) Journal Publishing DTD v1.1d3 20150301//EN" "http://jats.nlm.nih.gov/publishing/1.1d3/JATS-journalpublishing1.dtd">
<article article-type="research-article" dtd-version="1.1d3" xml:lang="en" xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">
<front>
<journal-meta>
<journal-id journal-id-type="nlm-ta">PLoS ONE</journal-id>
<journal-id journal-id-type="publisher-id">plos</journal-id>
<journal-id journal-id-type="pmc">plosone</journal-id>
<journal-title-group>
<journal-title>PLOS ONE</journal-title>
</journal-title-group>
<issn pub-type="epub">1932-6203</issn>
<publisher>
<publisher-name>Public Library of Science</publisher-name>
<publisher-loc>San Francisco, CA USA</publisher-loc>
</publisher>
</journal-meta>
<article-meta>
<article-id pub-id-type="doi">10.1371/journal.pone.0313320</article-id>
<article-id pub-id-type="publisher-id">PONE-D-24-29326</article-id>
<article-categories>
<subj-group subj-group-type="heading">
<subject>Research Article</subject>
</subj-group>
<subj-group subj-group-type="Discipline-v3">
<subject>Biology and life sciences</subject><subj-group><subject>Anatomy</subject><subj-group><subject>Body fluids</subject><subj-group><subject>Saliva</subject></subj-group></subj-group></subj-group></subj-group><subj-group subj-group-type="Discipline-v3">
<subject>Medicine and health sciences</subject><subj-group><subject>Anatomy</subject><subj-group><subject>Body fluids</subject><subj-group><subject>Saliva</subject></subj-group></subj-group></subj-group></subj-group><subj-group subj-group-type="Discipline-v3">
<subject>Biology and life sciences</subject><subj-group><subject>Physiology</subject><subj-group><subject>Body fluids</subject><subj-group><subject>Saliva</subject></subj-group></subj-group></subj-group></subj-group><subj-group subj-group-type="Discipline-v3">
<subject>Medicine and health sciences</subject><subj-group><subject>Clinical medicine</subject><subj-group><subject>Signs and symptoms</subject><subj-group><subject>Dehydration (medicine)</subject></subj-group></subj-group></subj-group></subj-group><subj-group subj-group-type="Discipline-v3">
<subject>Biology and life sciences</subject><subj-group><subject>Anatomy</subject><subj-group><subject>Body fluids</subject><subj-group><subject>Urine</subject></subj-group></subj-group></subj-group></subj-group><subj-group subj-group-type="Discipline-v3">
<subject>Medicine and health sciences</subject><subj-group><subject>Anatomy</subject><subj-group><subject>Body fluids</subject><subj-group><subject>Urine</subject></subj-group></subj-group></subj-group></subj-group><subj-group subj-group-type="Discipline-v3">
<subject>Biology and life sciences</subject><subj-group><subject>Physiology</subject><subj-group><subject>Body fluids</subject><subj-group><subject>Urine</subject></subj-group></subj-group></subj-group></subj-group><subj-group subj-group-type="Discipline-v3">
<subject>Biology and life sciences</subject><subj-group><subject>Physiology</subject><subj-group><subject>Physiological parameters</subject><subj-group><subject>Body weight</subject></subj-group></subj-group></subj-group></subj-group><subj-group subj-group-type="Discipline-v3">
<subject>Physical sciences</subject><subj-group><subject>Chemistry</subject><subj-group><subject>Chemical properties</subject><subj-group><subject>Specific gravity</subject></subj-group></subj-group></subj-group></subj-group><subj-group subj-group-type="Discipline-v3">
<subject>Physical sciences</subject><subj-group><subject>Chemistry</subject><subj-group><subject>Physical chemistry</subject><subj-group><subject>Chemical properties</subject><subj-group><subject>Specific gravity</subject></subj-group></subj-group></subj-group></subj-group></subj-group><subj-group subj-group-type="Discipline-v3">
<subject>Engineering and technology</subject><subj-group><subject>Measurement</subject></subj-group></subj-group><subj-group subj-group-type="Discipline-v3">
<subject>Biology and life sciences</subject><subj-group><subject>Nutrition</subject><subj-group><subject>Diet</subject></subj-group></subj-group></subj-group><subj-group subj-group-type="Discipline-v3">
<subject>Medicine and health sciences</subject><subj-group><subject>Nutrition</subject><subj-group><subject>Diet</subject></subj-group></subj-group></subj-group><subj-group subj-group-type="Discipline-v3">
<subject>Biology and life sciences</subject><subj-group><subject>Physiology</subject><subj-group><subject>Physiological parameters</subject><subj-group><subject>Body weight</subject><subj-group><subject>Weight loss</subject></subj-group></subj-group></subj-group></subj-group></subj-group></article-categories>
<title-group>
<article-title>Reliability and minimal detectable change of the MX3 hydration testing system</article-title>
<alt-title alt-title-type="running-head">Reliability of MX3</alt-title>
</title-group>
<contrib-group>
<contrib contrib-type="author" xlink:type="simple">
<name name-style="western">
<surname>Winter</surname>
<given-names>Ian</given-names>
</name>
<role content-type="http://credit.niso.org/contributor-roles/conceptualization/">Conceptualization</role>
<role content-type="http://credit.niso.org/contributor-roles/formal-analysis/">Formal analysis</role>
<role content-type="http://credit.niso.org/contributor-roles/investigation/">Investigation</role>
<role content-type="http://credit.niso.org/contributor-roles/methodology/">Methodology</role>
<role content-type="http://credit.niso.org/contributor-roles/visualization/">Visualization</role>
<role content-type="http://credit.niso.org/contributor-roles/writing-original-draft/">Writing – original draft</role>
<role content-type="http://credit.niso.org/contributor-roles/writing-review-editing/">Writing – review &amp; editing</role>
<xref ref-type="aff" rid="aff001"><sup>1</sup></xref>
</contrib>
<contrib contrib-type="author" xlink:type="simple">
<name name-style="western">
<surname>Burdin</surname>
<given-names>Josie</given-names>
</name>
<role content-type="http://credit.niso.org/contributor-roles/investigation/">Investigation</role>
<role content-type="http://credit.niso.org/contributor-roles/writing-review-editing/">Writing – review &amp; editing</role>
<xref ref-type="aff" rid="aff002"><sup>2</sup></xref>
</contrib>
<contrib contrib-type="author" corresp="yes" xlink:type="simple">
<contrib-id authenticated="true" contrib-id-type="orcid">https://orcid.org/0000-0003-4052-5023</contrib-id>
<name name-style="western">
<surname>Wilson</surname>
<given-names>Patrick B.</given-names>
</name>
<role content-type="http://credit.niso.org/contributor-roles/conceptualization/">Conceptualization</role>
<role content-type="http://credit.niso.org/contributor-roles/formal-analysis/">Formal analysis</role>
<role content-type="http://credit.niso.org/contributor-roles/methodology/">Methodology</role>
<role content-type="http://credit.niso.org/contributor-roles/project-administration/">Project administration</role>
<role content-type="http://credit.niso.org/contributor-roles/resources/">Resources</role>
<role content-type="http://credit.niso.org/contributor-roles/supervision/">Supervision</role>
<role content-type="http://credit.niso.org/contributor-roles/writing-original-draft/">Writing – original draft</role>
<role content-type="http://credit.niso.org/contributor-roles/writing-review-editing/">Writing – review &amp; editing</role>
<xref ref-type="aff" rid="aff003"><sup>3</sup></xref>
<xref ref-type="corresp" rid="cor001">*</xref>
</contrib>
</contrib-group>
<aff id="aff001"><label>1</label> <addr-line>Human Performance Laboratory, School of Exercise Science, Old Dominion University, Norfolk, VA, United States of America</addr-line></aff>
<aff id="aff002"><label>2</label> <addr-line>School of Rehabilitation Sciences, Old Dominion University, Norfolk, VA, United States of America</addr-line></aff>
<aff id="aff003"><label>3</label> <addr-line>Associate Professor of Exercise Science, Human Performance Laboratory, School of Exercise Science, Old Dominion University, Norfolk, VA, United States of America</addr-line></aff>
<contrib-group>
<contrib contrib-type="editor" xlink:type="simple">
<name name-style="western">
<surname>Adams</surname>
<given-names>William M.</given-names>
</name>
<role>Editor</role>
<xref ref-type="aff" rid="edit1"/>
</contrib>
</contrib-group>
<aff id="edit1"><addr-line>United States Olympic &amp; Paralympic Committee, UNITED STATES OF AMERICA</addr-line></aff>
<author-notes>
<fn fn-type="conflict" id="coi001">
<p>The authors have declared that no competing interests exist.</p>
</fn>
<corresp id="cor001">* E-mail: <email xlink:type="simple">pbwilson@odu.edu</email></corresp>
</author-notes>
<pub-date pub-type="epub">
<day>21</day>
<month>11</month>
<year>2024</year>
</pub-date>
<pub-date pub-type="collection">
<year>2024</year>
</pub-date>
<volume>19</volume>
<issue>11</issue>
<elocation-id>e0313320</elocation-id>
<history>
<date date-type="received">
<day>16</day>
<month>7</month>
<year>2024</year>
</date>
<date date-type="accepted">
<day>22</day>
<month>10</month>
<year>2024</year>
</date>
</history>
<permissions>
<copyright-year>2024</copyright-year>
<copyright-holder>Winter et al</copyright-holder>
<license xlink:href="http://creativecommons.org/licenses/by/4.0/" xlink:type="simple">
<license-p>This is an open access article distributed under the terms of the <ext-link ext-link-type="uri" xlink:href="http://creativecommons.org/licenses/by/4.0/" xlink:type="simple">Creative Commons Attribution License</ext-link>, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.</license-p>
</license>
</permissions>
<self-uri content-type="pdf" xlink:href="info:doi/10.1371/journal.pone.0313320"/>
<abstract>
<p>Assessing hydration status outside of laboratories can be challenging given that most hydration measures are invasive, stationary, costly, or have questionable validity. This study investigated the within-day, test-retest reliability, and minimal detectable change (MDC) of the MX3 Hydration Testing System (MX3 Diagnostics), a relatively low cost, noninvasive, and portable method to measure saliva osmolality. Seventy-five adults (44 men, 31 women; 29.6±10.8 yr, 171.1±9.2 cm, 79.1±15.4 kg) presented two saliva samples approximately 3 to 5 minutes apart. Fluid intake was avoided for at least 5 minutes prior to sample collections. For each sample collection, a researcher used the MX3 to tap the tip of a test strip to saliva on a participant’s tongue. Intra-class correlation coefficients (ICCs) and MDC were calculated as measures of reliability. Means for the two measurements were 64.3±19.0 mOsm and 65.5±17.9 mOsm (mean difference of -1.2±13.0 mOsm; t = -0.806, p = 0.423). Further analysis with a two-one-sided test procedure revealed equivalence between the two SOSM measurements (p &lt; 0.001 for upper and lower bounds). Within-day repeat measures yielded an ICC of 0.75 and an MDC at the 90% confidence level of 21.3 mOsm. With moderate-to-good reliability, the MX3 appears to be a practical choice for reliably measuring moderate-sized changes (&gt;20 mOsm) in saliva osmolality outside of laboratory constraints.</p>
</abstract>
<funding-group>
<funding-statement>The author(s) received no specific funding for this work.</funding-statement>
</funding-group>
<counts>
<fig-count count="2"/>
<table-count count="1"/>
<page-count count="9"/>
</counts>
<custom-meta-group>
<custom-meta id="data-availability">
<meta-name>Data Availability</meta-name>
<meta-value>All relevant data are within the manuscript and its <xref ref-type="sec" rid="sec010">Supporting Information</xref> files.</meta-value>
</custom-meta>
</custom-meta-group>
</article-meta>
</front>
<body>
<sec id="sec001" sec-type="intro">
<title>Introduction</title>
<p>Hypohydration, an inadequate hydration status, can result in both cognitive and physical impairments [<xref ref-type="bibr" rid="pone.0313320.ref001">1</xref>, <xref ref-type="bibr" rid="pone.0313320.ref002">2</xref>]. Not only can hypohydration impair cognitive and physical function, but reduced body fluid storage can decrease sweat rate [<xref ref-type="bibr" rid="pone.0313320.ref003">3</xref>]. This can be particularly detrimental as evaporative cooling from sweat is the human body’s primary means of thermoregulation in the heat [<xref ref-type="bibr" rid="pone.0313320.ref003">3</xref>]. According to a joint position statement from the American College of Sports Medicine, Academy of Nutrition and Dietetics, and Dietitians of Canada, decreases in exercise performance become apparent when hypohydration exceeds 2% of body weight, substantial when fluid losses exceed 5% of body weight, and when fluid losses approach 6–10% of body weight, heat stroke and heat exhaustion can ensue [<xref ref-type="bibr" rid="pone.0313320.ref001">1</xref>].</p>
<p>Several methods exist to assess hydration status at the individual level, including plasma osmolality, urine osmolality, urine specific gravity, urine color, changes in body weight, and more [<xref ref-type="bibr" rid="pone.0313320.ref004">4</xref>]. However, no single recognized gold standard of hydration status exists, although plasma osmolality, electrolyte lab values, and blood urea nitrogen to creatinine ratio (BUN:Cr) are frequently utilized as reference methods in clinical settings [<xref ref-type="bibr" rid="pone.0313320.ref005">5</xref>]. The majority of frequently utilized hydration status measures are invasive, stationary, and/or costly, indicating the need for less-invasive, less-costly, portable, reliable, and valid tools. Assessing hydration status outside of laboratories (e.g., field settings) has presented a long-standing challenge [<xref ref-type="bibr" rid="pone.0313320.ref006">6</xref>], but technological advances are allowing some of the barriers around portability and cost to be overcome.</p>
<p>Saliva osmolality (SOSM), which is the number of solute particles per kilogram of saliva, is one hydration biomarker that potentially addresses the concerns around invasiveness, cost, and portability associated with other methods. Muñoz and colleagues [<xref ref-type="bibr" rid="pone.0313320.ref007">7</xref>] assessed several hydration biomarkers during active and passive dehydration and found SOSM to be a sensitive, specific, and valid measure of hydration status during active periods of hypohydration (i.e., physical activity in the heat). These results suggest SOSM can be used alongside commonly used hydration assessment methods, such as changes in body mass and urine specific gravity. Additionally, other studies, conducted in both sport and clinical settings, indicate SOSM may represent a valid and reliable marker for hydration status [<xref ref-type="bibr" rid="pone.0313320.ref005">5</xref>, <xref ref-type="bibr" rid="pone.0313320.ref006">6</xref>, <xref ref-type="bibr" rid="pone.0313320.ref008">8</xref>]. While research suggests that SOSM is a viable metric for evaluating hydration status, the commercial development of such devices that measure SOSM has been limited. Recently, however, a handheld portable device that tests SOSM has been developed by MX3 Diagnostics (Austin, TX) and is currently available for purchase.</p>
<p>The MX3 Hydration Testing System (HTS) is a portable, handheld osmometer developed for point-of-care, spot SOSM measurement. Limited research has been published on the MX3 HTS, with little-to-no data on its reliability. However, a small number of studies have utilized the MX3 HTS to detect hypohydration in clinical populations [<xref ref-type="bibr" rid="pone.0313320.ref009">9</xref>, <xref ref-type="bibr" rid="pone.0313320.ref010">10</xref>]. Given that SOSM has shown more between-person and day-to-day variability than plasma osmolality and urine specific gravity [<xref ref-type="bibr" rid="pone.0313320.ref011">11</xref>, <xref ref-type="bibr" rid="pone.0313320.ref012">12</xref>], evaluating the reliability of this handheld saliva osmometer under a variety of conditions is important. No known study to date has assessed the within-day, test-retest reliability, and minimal detectable change (MDC) of the MX3 HTS for the assessment of saliva osmolality. The MDC represents the minimum change that, with a specified degree of confidence, can be considered as greater than measurement error [<xref ref-type="bibr" rid="pone.0313320.ref013">13</xref>]. In practical terms, the MDC is useful because it provides a benchmark for researchers and practitioners to determine whether an observed change in a given individual is likely to be true change. Thus, the purpose of this investigation was to determine the within-day, test-retest reliability, and MDC of the MX3 HTS.</p>
</sec>
<sec id="sec002" sec-type="materials|methods">
<title>Materials and methods</title>
<sec id="sec003">
<title>Participants</title>
<p>A total of 75 individuals (44 men, 31 women; 29.6±10.8 yr, 171.1±9.2 cm, 79.1±15.4 kg) volunteered to participate in this study. Participants were recruited via convenience sampling through multiple avenues in the Hampton Roads, Virginia area. Individuals were eligible for study inclusion if they were at least 18 years of age, weighed under 330 pounds, did not have an implanted electrical device (i.e., pacemaker), and were not pregnant. The latter three criteria were related to a different aim of the study that involved examining the associations between body composition (measured via bioelectrical impedance) and SOSM. Recruitment and enrollment for the study lasted from May 24<sup>th</sup>, 2023 until April 30<sup>th</sup>, 2024.</p>
</sec>
<sec id="sec004">
<title>Ethics</title>
<p>The protocols and procedures for this original research were submitted to and approved by Old Dominion University’s Institutional Review Board (reference #23–058). Prior to study participation and data collection, potential participants went through an informed consent process in which the procedures, inclusion criteria, potential risks and benefits, etc. were explained, and they were given the option to choose to either participate or not. Individuals agreeing to participate provided their written consent. Precautions were taken to ensure participants’ identifiable data remained confidential.</p>
</sec>
<sec id="sec005" sec-type="materials|methods">
<title>Procedures</title>
<p>A variety of locations were used for assessments given the portability of the MX3 HTS device involved in data collection; locations included the Human Performance Laboratory at Old Dominion University, as well as several local gyms and a weightlifting event. Procedures were not altered based on the location of data collection. After signing an informed consent document, any individuals that had fluids with them were asked to refrain from drinking throughout the remainder of testing, including for at least 5 minutes prior to obtaining the initial saliva sample, due to the impact of recent fluid intake on SOSM [<xref ref-type="bibr" rid="pone.0313320.ref012">12</xref>]. Participants completed a questionnaire inquiring about age, sex, race/ethnicity, exercise/physical activity habits, and recent fluid intake. For exercise/physical activity habits, participants could select between sedentary, lightly active, moderately active, and highly active. Total fluid intake over the past 4 hours was assessed using a fill-in-the-blank option.</p>
<p>Subsequently, participants were asked to generate a fresh saliva sample (i.e., new saliva generated after swallowing all existing saliva) and present the sample on their tongue with an open mouth. Using the MX3 HTS, a researcher then tapped the tip of a test strip to the saliva while the participant’s mouth remained open. After 10–15 seconds, the MX3 HTS provided a SOSM value along with a respective hydration status category. Participants were categorized as hydrated if SOSM was &lt;65 mOsm, mildly dehydrated if SOSM was 65–99 mOsm, moderately dehydrated if SOSM was 100–150 mOsm, or severely dehydrated if SOSM was &gt;150 mOsm [<xref ref-type="bibr" rid="pone.0313320.ref014">14</xref>]. All three investigators were involved in the sampling, though one investigator (IW) collected more than 90% of the saliva samples. Two of the researchers were Registered Dietitians, while the third was an undergraduate exercise science student. Using sampling guidelines provided by MX3 Diagnostics, all three investigators practiced using the MX3 on multiple occasions prior to using the device for data collection.</p>
<p>After the first SOSM assessment, participants’ heights were measured using a stadiometer and body composition was evaluated using an OMRON Full Body Composition Monitor Scale (HBF-514C; Omron Healthcare, Inc., Lake Forrest, IL), which uses bioelectrical impedance analysis. Before the scan, participants were asked to wipe down the palms of their hands and soles of their feet with a moist wipe. Researchers inputted each participant’s height, age, and sex into the HBF-514C, which was followed by a period of approximately 30 seconds in which participants stood on the platform and held on to an attached handle with arms out forward and extended for the duration of the scan.</p>
<p>Next, SOSM was assessed a second time using the same process as the first assessment. Time between the two SOSM assessments was approximately 3–5 minutes, short enough for the investigators to not expect real changes in hydration status.</p>
</sec>
<sec id="sec006">
<title>Statistics</title>
<p>SPSS software (version 29, IBM, Armonk, NY) and Microsoft Excel (2013 version, Microsoft, Redmond, WA) were used for statistical analyses. Specifically, SPSS was used to calculate descriptive statistics and intra-class correlation coefficients (ICC), while Microsoft Excel was used to generate standard error of the measurement (SEM) and MDC values. The distribution of variables was assessed by examining histograms and Q-Q plots. The data for the first SOSM measurement had one clear outlier (&gt;4 standard deviations [SDs] from the mean), while the second SOSM measurement values had a relatively normal distribution. Removal of the participant with the outlier value for the first SOSM measurement had no meaningful impact on the results, and therefore the analyses using all participants are presented.</p>
<p>An unpaired t-test was used to determine whether there were any differences in SOSM between those who were sampled in the morning vs. the afternoon. A paired t-test was run to test the null hypothesis that the mean difference between the two measurements was 0. Cohen’s <italic>d</italic> values were also calculated, using the average of variances in the denominator. The equivalence of the two SOSM measurements was evaluated via a two-one-sided test (TOST) procedure [<xref ref-type="bibr" rid="pone.0313320.ref015">15</xref>] within jamovi [<xref ref-type="bibr" rid="pone.0313320.ref016">16</xref>], using the paired-samples t-test option. The TOST procedure tests whether the following hypothesis can be rejected: the difference between measurements is at least as extreme as the smallest effect size (bounds) of interest [<xref ref-type="bibr" rid="pone.0313320.ref015">15</xref>]. For this study, the lower and upper equivalence bounds were set at Cohen’s <italic>d</italic><sub><italic>z</italic></sub> of -0.5 and +0.5, respectively [<xref ref-type="bibr" rid="pone.0313320.ref015">15</xref>]. Measurements were deemed to be equivalent if the two one-sided t-tests both showed statistical significance at an α &lt; 0.05.</p>
<p>The ICCs and SEM were calculated to assess the reliability of repeated SOSM measurements. The within-day ICC was based on two SOSM measurements using a two-way mixed, absolute agreement, single measures method [<xref ref-type="bibr" rid="pone.0313320.ref017">17</xref>]. MDC values were calculated using the following formula: SEM × √2 × z-score for the desired confidence interval (CI) [<xref ref-type="bibr" rid="pone.0313320.ref018">18</xref>, <xref ref-type="bibr" rid="pone.0313320.ref019">19</xref>]. This study employed 80% (MDC<sub>80</sub>) and 90% (MDC<sub>90</sub>) CIs; thus, the formulas used were ‘SEM × √2 × 1.282’ and ‘SEM × √2 × 1.645’, respectively. The SEM was calculated as follows: SD x √ (1-ICC), where the SD was a pooled value from all SOSM observations.</p>
<p>A Bland-Altman plot was created to evaluate bias between differences in the first and second SOSM measurements and estimate an agreement interval [<xref ref-type="bibr" rid="pone.0313320.ref020">20</xref>]. Within the Bland-Altman plot, horizontal lines were plotted on the y-axis to indicate the mean difference in measurements (bias) and 95% limits of agreement (precision). A regression line was also fitted to the Bland-Altman plot and used to test for proportional bias. In addition, a scatterplot was created with the first SOSM measurement on the x-axis and the second SOSM measurement on the y-axis. A linear regression line and line of identity (x = y) were included to compare the regression with hypothetical perfect agreement. Proportional bias was evaluated based on whether the regression slope’s 95% CI included 1.0.</p>
<p>A two-sided p-value ≤ 0.05 was used as the threshold for determining significance. Descriptive statistics are reported as mean±SD.</p>
</sec>
</sec>
<sec id="sec007" sec-type="results">
<title>Results</title>
<p>Among the 75 adults who participated, mean body fat percentage was 28.6±8.1%, while mean fluid intake four hours prior to assessment was 0.791±0.596 L among 72 participants (three participants did not provide a value for fluid intake). In terms of activity level, 29 participants described themselves as highly active (38.7%), 35 as moderately active (46.7%), nine as lightly active (12.0%), and two as sedentary (2.7%). Of all participants, four self-reported as Asian or Pacific Islander (5.3%), five as black or African American (6.7%), one as Hispanic or Latino (1.3%), one as other race (1.3%), 58 as white (77.3%), and six as two or more races/ethnicities (8.0%).</p>
<p>The means of the first and second SOSM measurements were 64.3±19.0 mOsm and 65.5±17.9 mOsm, respectively (mean difference of -1.2±13.0 mOsm; t = -0.806, p = 0.423, Cohen’s <italic>d</italic> = -0.07). The TOST procedure revealed equivalence between the two SOSM measurements (both tests for upper and lower bounds had a p &lt; 0.001).</p>
<p>For the first SOSM measurement, 42 participants were categorized as hydrated (56.0%), 31 as mildly dehydrated (41.3%), and two as moderately dehydrated (2.7%). For the second SOSM measurement, 39 participants were categorized as hydrated (52.0%), 31 as mildly dehydrated (41.3%), and five as moderately dehydrated (6.7%).</p>
<p>Twenty-eight (37.3%) participants had SOSM measurements taken in the morning (before noon), while 47 (62.7%) were sampled in the afternoon. There was no significant difference in average SOSM between those sampled in the morning versus those sampled in the afternoon (65.4±19.7 vs. 64.6±15.8 mOsm; t = 0.203, p = 0.839, Cohen’s <italic>d</italic> = 0.05).</p>
<p><bold><xref ref-type="fig" rid="pone.0313320.g001">Fig 1</xref></bold> is a Bland-Altman plot that shows the individual differences between first and second SOSM measurements versus the mean of the two measurements, with horizontal lines depicting 95% limits of agreement and the mean difference between measurements. The regression co-efficient was 0.07 with a 95% CI that covered 0 (-0.11, 0.24), indicating an absence of obvious proportional bias. However, in <bold><xref ref-type="fig" rid="pone.0313320.g002">Fig 2</xref></bold>, which shows the regression of the first and second SOSM measurements along with a line of identity, there did appear to be some evidence of proportional bias, with a co-efficient of 0.71 (95% CI: 0.56, 0.85) that was different from 1.0.</p>
<fig id="pone.0313320.g001" position="float">
<object-id pub-id-type="doi">10.1371/journal.pone.0313320.g001</object-id>
<label>Fig 1</label>
<caption>
<title>Bland-Altman plot showing the individual differences in SOSM measurements 1 and 2 by the average of the two measurements.</title>
<p>The mean difference (black), 95% limits of agreement (dashed), and regression (grey) lines are shown.</p>
</caption>
<graphic mimetype="image" position="float" xlink:href="info:doi/10.1371/journal.pone.0313320.g001" xlink:type="simple"/>
</fig>
<fig id="pone.0313320.g002" position="float">
<object-id pub-id-type="doi">10.1371/journal.pone.0313320.g002</object-id>
<label>Fig 2</label>
<caption>
<title>Scatterplot of the two SOSM measurements with a regression line (black) and a line of identity (grey).</title>
</caption>
<graphic mimetype="image" position="float" xlink:href="info:doi/10.1371/journal.pone.0313320.g002" xlink:type="simple"/>
</fig>
<p>The ICC, MDC<sub>80</sub>, and MDC<sub>90</sub> values of SOSM were 0.75, 16.6 mOsm, and 21.3 mOsm respectively. All within-day, test-retest reliability statistics are displayed in <bold><xref ref-type="table" rid="pone.0313320.t001">Table 1</xref></bold>.</p>
<table-wrap id="pone.0313320.t001" position="float">
<object-id pub-id-type="doi">10.1371/journal.pone.0313320.t001</object-id>
<label>Table 1</label> <caption><title>Within-day reliability statistics.</title></caption>
<alternatives>
<graphic id="pone.0313320.t001g" mimetype="image" position="float" xlink:href="info:doi/10.1371/journal.pone.0313320.t001" xlink:type="simple"/>
<table>
<colgroup>
<col align="left" valign="middle"/>
<col align="left" valign="middle"/>
</colgroup>
<thead>
<tr>
<th align="center" colspan="2">SOSM measure 1 versus SOSM measure 2</th>
</tr>
</thead>
<tbody>
<tr>
<td align="left"><bold>ICC</bold></td>
<td align="left">0.75 (95%CI: 0.63, 0.84)</td>
</tr>
<tr>
<td align="left"><bold>SD</bold></td>
<td align="left">18.4</td>
</tr>
<tr>
<td align="left"><bold>SEM</bold></td>
<td align="left">9.2</td>
</tr>
<tr>
<td align="left"><bold>MDC</bold><sub><bold>80</bold></sub></td>
<td align="left">16.6</td>
</tr>
<tr>
<td align="left"><bold>MDC</bold><sub><bold>90</bold></sub></td>
<td align="left">21.3</td>
</tr>
</tbody>
</table>
</alternatives>
<table-wrap-foot>
<fn id="t001fn001"><p>CI, confidence interval; ICC, intra-class correlation; SD, standard deviation; SEM, standard error of the measurement; MDC<sub>80</sub>, minimal detectable change at the 80% confidence level; MDC<sub>90</sub>, minimal detectable change at the 90% confidence level.</p></fn>
</table-wrap-foot>
</table-wrap>
</sec>
<sec id="sec008" sec-type="conclusions">
<title>Discussion</title>
<p>Although studies have used the MX3 HTS to detect hypohydration [<xref ref-type="bibr" rid="pone.0313320.ref009">9</xref>, <xref ref-type="bibr" rid="pone.0313320.ref010">10</xref>], to the investigators’ knowledge no known study has investigated the reliability of the device for the assessment of saliva osmolality. The primary goal of this investigation was to assess the within-day, test-retest reliability of this portable handheld osmometer using multiple spot saliva samples. As ICC is widely used to assess test-retest reliability [<xref ref-type="bibr" rid="pone.0313320.ref017">17</xref>], this was a main outcome measure in determining reliability of the MX3 HTS. Within-day repeat SOSM measures using the MX3 HTS yielded an ICC of 0.75, which corresponds to a moderate-to-good reliability [<xref ref-type="bibr" rid="pone.0313320.ref017">17</xref>]. Based on a MDC<sub>90</sub> from this ICC, a change in SOSM of 21.3 mOsm or greater would need to be observed in order to be highly confident that this represents true change and not measurement error [<xref ref-type="bibr" rid="pone.0313320.ref013">13</xref>]. Thus, it is with 90% confidence that any repeat measurements that fall within ± 21.3 mOsm of an initial measurement may not represent a real change in SOSM.</p>
<p>It should be noted that a direct comparison of SOSM from two separate spot samples is likely to result in lower test-retest reliability than if both measurements were taken from the same saliva sample (i.e., one saliva sample collected in a sampling tube). While testing of the same saliva sample may provide results more indicative of true device test-retest reliability, the reliability from two separate serial measurements (like those used in the present study) is more realistic in terms of how the MX3 HTS is utilized in field settings (i.e., assess and track changes in hydration status using separate saliva samples over time). Given its minimally invasive procedures, low-cost, and timeliness, taking an average of two back-to-back SOSM readings may be one strategy to improve the reliability of spot samples, as this has been a suggestion in other human assessment reliability studies [<xref ref-type="bibr" rid="pone.0313320.ref021">21</xref>, <xref ref-type="bibr" rid="pone.0313320.ref022">22</xref>].</p>
<p>There were somewhat contradictory results with regards to evidence of proportional bias. Based on results presented in <bold><xref ref-type="fig" rid="pone.0313320.g002">Fig 2</xref></bold>, it appears that there may be some proportional bias present, though this was not obvious in the Bland-Altman plot (<bold><xref ref-type="fig" rid="pone.0313320.g001">Fig 1</xref></bold>). Given that relatively few participants in this study had SOSM values in the moderately or severely dehydrated categories, additional research with larger numbers of participants across the full spectrum of hydration status would be helpful in confirming or refuting the presence of proportional bias. This could involve investigations in which hydration status is experimentally manipulated before serial SOSM measurements are taken.</p>
<p>The investigators of the present study did not assess the validity of the MX3 in comparison to other validated, laboratory-grade osmometers; however, two reports have done so and found the MX3 HTS to be valid against the Osmette III (Precision Systems Inc., Calumet City, IL) and Model 3320 (Advanced Instruments, Norwood, MA) benchtop osmometers [<xref ref-type="bibr" rid="pone.0313320.ref023">23</xref>, <xref ref-type="bibr" rid="pone.0313320.ref024">24</xref>]. Rather, the values of repeat SOSM measurements were the main interest in the present study, not the respective hydration status categorization provided by the MX3 HTS. With that said, the categorization of hydration status according to SOSM from the MX3 HTS should be interpreted with caution given inter- and intra-individual variation in baseline saliva SOSM [<xref ref-type="bibr" rid="pone.0313320.ref011">11</xref>, <xref ref-type="bibr" rid="pone.0313320.ref014">14</xref>] and potential interference from recent food, drink, gum, or tobacco consumption [<xref ref-type="bibr" rid="pone.0313320.ref012">12</xref>].</p>
<p>This study is not without limitations. It may have been more ideal for the waiting period between last time of fluid or food consumption and saliva sampling to be longer (e.g., 15 minutes) [<xref ref-type="bibr" rid="pone.0313320.ref012">12</xref>]. Furthermore, if water or a sports drink containing electrolytes and carbohydrates was consumed less than 15 minutes prior to the initial SOSM measurement, then there is a chance SOSM was misclassified [<xref ref-type="bibr" rid="pone.0313320.ref014">14</xref>]. Another limitation is that there was no systematic assessment of exercise in the hours prior to data collection. Some participants were likely to have exercised, which could raise SOSM and theoretically affect the reliability of the MX3. For example, if a person is hypohydrated due to exercise, they may have more difficulty producing saliva consistently [<xref ref-type="bibr" rid="pone.0313320.ref025">25</xref>]. Despite one investigator assessing the vast majority of saliva samples with the MX3 HTS, all three investigators did so at some point during the study, so there is a chance that between-investigator differences in exact sampling technique may have affected SOSM measurements. Future research should address concerns with inter-user reliability and how, if at all, test-retest reliability of the MX3 HTS is altered when repeated measurements are taken immediately after one another instead of with a 3-5-minute gap. Additionally, more research is needed to establish the validity of the MX3 HTS in comparison to other previously validated, laboratory-grade osmometers.</p>
</sec>
<sec id="sec009" sec-type="conclusions">
<title>Conclusions</title>
<p>This study found that the MX3 HTS demonstrates moderate-to-good reliability for the assessment of saliva osmolality. Given its relatively low-cost, noninvasive procedures, portability, near-immediate results, and moderate-to-good reliability, the MX3 HTS appears to be a reasonable and practical choice for reliably measuring moderate-sized changes (i.e., greater than 20 mOsm) in saliva osmolality. These results suggest this tool may be useful for tracking changes in hydration in field settings where hydration status is crucial to performance.</p>
</sec>
<sec id="sec010" sec-type="supplementary-material">
<title>Supporting information</title>
<supplementary-material id="pone.0313320.s001" mimetype="application/vnd.openxmlformats-officedocument.spreadsheetml.sheet" position="float" xlink:href="info:doi/10.1371/journal.pone.0313320.s001" xlink:type="simple">
<label>S1 Dataset</label>
<caption>
<title/>
<p>(XLSX)</p>
</caption>
</supplementary-material>
</sec>
</body>
<back>
<ref-list>
<title>References</title>
<ref id="pone.0313320.ref001"><label>1</label><mixed-citation publication-type="journal" xlink:type="simple"><name name-style="western"><surname>Thomas</surname> <given-names>DT</given-names></name>, <name name-style="western"><surname>Erdman</surname> <given-names>KA</given-names></name>, <name name-style="western"><surname>Burke</surname> <given-names>LM</given-names></name>. <article-title>American College of Sports Medicine joint position statement. nutrition and athletic performance</article-title>. <source>Med Sci Sports Exerc.</source> <year>2016</year>;<volume>48</volume>(<issue>3</issue>):<fpage>543</fpage>–<lpage>568</lpage>. <comment>doi: <ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1249/MSS.0000000000000852" xlink:type="simple">10.1249/MSS.0000000000000852</ext-link></comment> <object-id pub-id-type="pmid">26891166</object-id></mixed-citation></ref>
<ref id="pone.0313320.ref002"><label>2</label><mixed-citation publication-type="journal" xlink:type="simple"><name name-style="western"><surname>Wittbrodt</surname> <given-names>MT</given-names></name>, <name name-style="western"><surname>Millard-Stafford</surname> <given-names>M</given-names></name>. <article-title>Dehydration impairs cognitive performance: A meta-analysis</article-title>. <source>Med Sci Sports Exerc</source>. <year>2018</year>;<volume>50</volume>(<issue>11</issue>):<fpage>2360</fpage>–<lpage>2368</lpage>. <comment>doi: <ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1249/MSS.0000000000001682" xlink:type="simple">10.1249/MSS.0000000000001682</ext-link></comment> <object-id pub-id-type="pmid">29933347</object-id></mixed-citation></ref>
<ref id="pone.0313320.ref003"><label>3</label><mixed-citation publication-type="journal" xlink:type="simple"><name name-style="western"><surname>Sawka</surname> <given-names>MN</given-names></name>, <name name-style="western"><surname>Cheuvront</surname> <given-names>SN</given-names></name>, <name name-style="western"><surname>Kenefick</surname> <given-names>RW</given-names></name>. <article-title>Hypohydration and human performance: impact of environment and physiological mechanisms</article-title>. <source>Sports Med</source>. <year>2015</year>;<volume>45</volume>(<issue>Suppl 1</issue>):<fpage>S51</fpage>–<lpage>60</lpage>. <comment>doi: <ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1007/s40279-015-0395-7" xlink:type="simple">10.1007/s40279-015-0395-7</ext-link></comment> <object-id pub-id-type="pmid">26553489</object-id></mixed-citation></ref>
<ref id="pone.0313320.ref004"><label>4</label><mixed-citation publication-type="journal" xlink:type="simple"><name name-style="western"><surname>Barley</surname> <given-names>OR</given-names></name>, <name name-style="western"><surname>Chapman</surname> <given-names>DW</given-names></name>, <name name-style="western"><surname>Abbiss</surname> <given-names>CR</given-names></name>. <article-title>Reviewing the current methods of assessing hydration in athletes.</article-title> <source>J Int Soc Sports Nutr</source>. <year>2020</year>;<volume>17</volume>(<issue>1</issue>):<fpage>52</fpage>. <comment>doi: <ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1186/s12970-020-00381-6" xlink:type="simple">10.1186/s12970-020-00381-6</ext-link></comment> <object-id pub-id-type="pmid">33126891</object-id></mixed-citation></ref>
<ref id="pone.0313320.ref005"><label>5</label><mixed-citation publication-type="journal" xlink:type="simple"><name name-style="western"><surname>Fortes</surname> <given-names>MB</given-names></name>, <name name-style="western"><surname>Owen</surname> <given-names>JA</given-names></name>, <name name-style="western"><surname>Raymond-Barker</surname> <given-names>P</given-names></name>, <name name-style="western"><surname>Bishop</surname> <given-names>C</given-names></name>, <name name-style="western"><surname>Elghenzai</surname> <given-names>S</given-names></name>, <name name-style="western"><surname>Oliver</surname> <given-names>SJ</given-names></name>, <etal>et al</etal>. <article-title>Is this elderly patient dehydrated? Diagnostic accuracy of hydration assessment using physical signs, urine, and saliva markers.</article-title> <source>J Am Med Dir Assoc</source>. <year>2015</year>;<volume>16</volume>(<issue>3</issue>):<fpage>221</fpage>–<lpage>228</lpage>. <comment>doi: <ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1016/j.jamda.2014.09.012" xlink:type="simple">10.1016/j.jamda.2014.09.012</ext-link></comment> <object-id pub-id-type="pmid">25444573</object-id></mixed-citation></ref>
<ref id="pone.0313320.ref006"><label>6</label><mixed-citation publication-type="journal" xlink:type="simple"><name name-style="western"><surname>Smith</surname> <given-names>DL</given-names></name>, <name name-style="western"><surname>Shalmiyeva</surname> <given-names>I</given-names></name>, <name name-style="western"><surname>DeBlois</surname> <given-names>J</given-names></name>, <name name-style="western"><surname>Winke</surname> <given-names>M</given-names></name>. <article-title>Use of salivary osmolality to assess dehydration.</article-title> <source>Prehosp Emerg Care</source>. <year>2012</year>;<volume>16</volume>(<issue>1</issue>):<fpage>128</fpage>–<lpage>135</lpage>. <comment>doi: <ext-link ext-link-type="uri" xlink:href="https://doi.org/10.3109/10903127.2011.614044" xlink:type="simple">10.3109/10903127.2011.614044</ext-link></comment> <object-id pub-id-type="pmid">21950414</object-id></mixed-citation></ref>
<ref id="pone.0313320.ref007"><label>7</label><mixed-citation publication-type="journal" xlink:type="simple"><name name-style="western"><surname>Muñoz</surname> <given-names>CX</given-names></name>, <name name-style="western"><surname>Johnson</surname> <given-names>EC</given-names></name>, <name name-style="western"><surname>DeMartini</surname> <given-names>JK</given-names></name>, <name name-style="western"><surname>Huggins</surname> <given-names>RA</given-names></name>, <name name-style="western"><surname>McKenzie</surname> <given-names>AL</given-names></name>, <name name-style="western"><surname>Casa</surname> <given-names>DJ</given-names></name>, <etal>et al</etal>. <article-title>Assessment of hydration biomarkers including salivary osmolality during passive and active dehydration.</article-title> <source>Eur J Clin Nutr</source>. <year>2013</year>;<volume>67</volume>(<issue>12</issue>):<fpage>1257</fpage>–<lpage>1263</lpage>. <comment>doi: <ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1038/ejcn.2013.195" xlink:type="simple">10.1038/ejcn.2013.195</ext-link></comment> <object-id pub-id-type="pmid">24129362</object-id></mixed-citation></ref>
<ref id="pone.0313320.ref008"><label>8</label><mixed-citation publication-type="journal" xlink:type="simple"><name name-style="western"><surname>Walsh</surname> <given-names>NP</given-names></name>, <name name-style="western"><surname>Laing</surname> <given-names>SJ</given-names></name>, <name name-style="western"><surname>Oliver</surname> <given-names>SJ</given-names></name>, <name name-style="western"><surname>Montague</surname> <given-names>JC</given-names></name>, <name name-style="western"><surname>Walters</surname> <given-names>R</given-names></name>, <name name-style="western"><surname>Bilzon</surname> <given-names>JLJ</given-names></name>. <article-title>Saliva parameters as potential indices of hydration status during acute dehydration.</article-title> <source>Med Sci Sports Exerc</source>. <year>2004</year>;<volume>36</volume>(<issue>9</issue>):<fpage>1535</fpage>–<lpage>1542</lpage>. <comment>doi: <ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1249/01.mss.0000139797.26760.06" xlink:type="simple">10.1249/01.mss.0000139797.26760.06</ext-link></comment> <object-id pub-id-type="pmid">15354035</object-id></mixed-citation></ref>
<ref id="pone.0313320.ref009"><label>9</label><mixed-citation publication-type="journal" xlink:type="simple"><name name-style="western"><surname>Atjo</surname> <given-names>NM</given-names></name>, <name name-style="western"><surname>Soraya</surname> <given-names>GV</given-names></name>, <name name-style="western"><surname>Natzir</surname> <given-names>R</given-names></name>, <name name-style="western"><surname>Kasyim</surname> <given-names>H</given-names></name>, <name name-style="western"><surname>Rasyid</surname> <given-names>H</given-names></name>, <name name-style="western"><surname>Chana</surname> <given-names>G</given-names></name>, <etal>et al</etal>. <article-title>Point-of-care saliva osmolarity testing for the screening of hydration in older adults with hypertension</article-title>. <source>J Am Med Dir Assoc</source>. <year>2022</year>;<volume>23</volume>(<issue>12</issue>):<fpage>1984.e9</fpage>–<lpage>1984.e14</lpage>. <comment>doi: <ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1016/j.jamda.2022.08.015" xlink:type="simple">10.1016/j.jamda.2022.08.015</ext-link></comment> <object-id pub-id-type="pmid">36174654</object-id></mixed-citation></ref>
<ref id="pone.0313320.ref010"><label>10</label><mixed-citation publication-type="journal" xlink:type="simple"><name name-style="western"><surname>Faidah</surname> <given-names>N</given-names></name>, <name name-style="western"><surname>Soraya</surname> <given-names>GV</given-names></name>, <name name-style="western"><surname>Erlichster</surname> <given-names>M</given-names></name>, <name name-style="western"><surname>Natzir</surname> <given-names>R</given-names></name>, <name name-style="western"><surname>Chana</surname> <given-names>G</given-names></name>, <name name-style="western"><surname>Skafidas</surname> <given-names>E</given-names></name>, <etal>et al</etal>. <article-title>Detection of voluntary dehydration in paediatric populations using non-invasive point-of-care saliva and urine testing.</article-title> <source>J Paediatr Child Health</source>. <year>2021</year>;<volume>57</volume>(<issue>6</issue>):<fpage>813</fpage>–<lpage>818</lpage>. <comment>doi: <ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1111/jpc.15325" xlink:type="simple">10.1111/jpc.15325</ext-link></comment> <object-id pub-id-type="pmid">33373495</object-id></mixed-citation></ref>
<ref id="pone.0313320.ref011"><label>11</label><mixed-citation publication-type="journal" xlink:type="simple"><name name-style="western"><surname>Cheuvront</surname> <given-names>SN</given-names></name>, <name name-style="western"><surname>Ely</surname> <given-names>BR</given-names></name>, <name name-style="western"><surname>Kenefick</surname> <given-names>RW</given-names></name>, <name name-style="western"><surname>Sawka</surname> <given-names>MN</given-names></name>. <article-title>Biological variation and diagnostic accuracy of dehydration assessment markers</article-title>. <source>Am J Clin Nutr</source>. <year>2010</year>;<volume>92</volume>(<issue>3</issue>):<fpage>565</fpage>–<lpage>573</lpage>. <comment>doi: <ext-link ext-link-type="uri" xlink:href="https://doi.org/10.3945/ajcn.2010.29490" xlink:type="simple">10.3945/ajcn.2010.29490</ext-link></comment> <object-id pub-id-type="pmid">20631205</object-id></mixed-citation></ref>
<ref id="pone.0313320.ref012"><label>12</label><mixed-citation publication-type="journal" xlink:type="simple"><name name-style="western"><surname>Ely</surname> <given-names>BR</given-names></name>, <name name-style="western"><surname>Cheuvront</surname> <given-names>SN</given-names></name>, <name name-style="western"><surname>Kenefick</surname> <given-names>RW</given-names></name>, <name name-style="western"><surname>Sawka</surname> <given-names>MN</given-names></name>. <article-title>Limitations of salivary osmolality as a marker of hydration status.</article-title> <source>Med Sci Sports Exerc</source>. <year>2011</year>;<volume>43</volume>(<issue>6</issue>):<fpage>1080</fpage>–<lpage>1084</lpage>. <comment>doi: <ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1249/MSS.0b013e3182058643" xlink:type="simple">10.1249/MSS.0b013e3182058643</ext-link></comment> <object-id pub-id-type="pmid">21088626</object-id></mixed-citation></ref>
<ref id="pone.0313320.ref013"><label>13</label><mixed-citation publication-type="journal" xlink:type="simple"><name name-style="western"><surname>Copay</surname> <given-names>AG</given-names></name>, <name name-style="western"><surname>Subach</surname> <given-names>BR</given-names></name>, <name name-style="western"><surname>Glassman</surname> <given-names>SD</given-names></name>, <name name-style="western"><surname>Polly</surname> <given-names>DW</given-names> <suffix>Jr</suffix></name>, <name name-style="western"><surname>Schuler</surname> <given-names>TC</given-names></name>. <article-title>Understanding the minimum clinically important difference: a review of concepts and methods.</article-title> <source>Spine J.</source> <year>2007</year>;<volume>7</volume>(<issue>5</issue>):<fpage>541</fpage>–<lpage>546</lpage>. <comment>doi: <ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1016/j.spinee.2007.01.008" xlink:type="simple">10.1016/j.spinee.2007.01.008</ext-link></comment> <object-id pub-id-type="pmid">17448732</object-id></mixed-citation></ref>
<ref id="pone.0313320.ref014"><label>14</label><mixed-citation publication-type="other" xlink:type="simple">MX3 Diagnostics. White Paper: Use of the MX3 hydration testing system. Available from: <ext-link ext-link-type="uri" xlink:href="https://www.mx3diagnostics.com/files/files/MX3HTS_WhitePaper_v1.2_070222.pdf" xlink:type="simple">https://www.mx3diagnostics.com/files/files/MX3HTS_WhitePaper_v1.2_070222.pdf</ext-link>.</mixed-citation></ref>
<ref id="pone.0313320.ref015"><label>15</label><mixed-citation publication-type="journal" xlink:type="simple"><name name-style="western"><surname>Lakens</surname> <given-names>D.</given-names></name> <article-title>Equivalence tests: A practical primer for t tests, correlations, and meta-analyses</article-title>. <source>Soc Psychol Pers Sci</source>. <year>2017</year>;<volume>8</volume>(<issue>4</issue>):<fpage>355</fpage>–<lpage>362</lpage>.</mixed-citation></ref>
<ref id="pone.0313320.ref016"><label>16</label><mixed-citation publication-type="journal" xlink:type="simple"><collab>The jamovi project</collab> (<year>2024</year>). <article-title><italic>jamovi</italic> (Version 2.5)</article-title> <source>[Computer Software].</source> Available from <ext-link ext-link-type="uri" xlink:href="https://www.jamovi.org" xlink:type="simple">https://www.jamovi.org</ext-link>.</mixed-citation></ref>
<ref id="pone.0313320.ref017"><label>17</label><mixed-citation publication-type="journal" xlink:type="simple"><name name-style="western"><surname>Koo</surname> <given-names>TK</given-names></name>, <name name-style="western"><surname>Li</surname> <given-names>MY</given-names></name>. <article-title>A guideline of selecting and reporting intraclass correlation coefficients for reliability research.</article-title> <source>J Chiropr Med</source>. <year>2016</year>;<volume>15</volume>(<issue>2</issue>):<fpage>155</fpage>–<lpage>163</lpage>. <comment>doi: <ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1016/j.jcm.2016.02.012" xlink:type="simple">10.1016/j.jcm.2016.02.012</ext-link></comment> <object-id pub-id-type="pmid">27330520</object-id></mixed-citation></ref>
<ref id="pone.0313320.ref018"><label>18</label><mixed-citation publication-type="journal" xlink:type="simple"><name name-style="western"><surname>Beaton</surname> <given-names>DE</given-names></name>, <name name-style="western"><surname>Bombardier</surname> <given-names>C</given-names></name>, <name name-style="western"><surname>Katz</surname> <given-names>JN</given-names></name>, <name name-style="western"><surname>Wright</surname> <given-names>JG</given-names></name>, <name name-style="western"><surname>Wells</surname> <given-names>G</given-names></name>, <name name-style="western"><surname>Boers</surname> <given-names>M</given-names></name>, <etal>et al</etal>. <article-title>Looking for important change/differences in studies of responsiveness. OMERACT MCID working group. Outcome measures in rheumatology. Minimal clinically important difference</article-title>. <source>J Rheumatol</source>. <year>2001</year>;<volume>28</volume>(<issue>2</issue>):<fpage>400</fpage>–<lpage>405</lpage>. <object-id pub-id-type="pmid">11246687</object-id></mixed-citation></ref>
<ref id="pone.0313320.ref019"><label>19</label><mixed-citation publication-type="journal" xlink:type="simple"><name name-style="western"><surname>Haley</surname> <given-names>SM</given-names></name>, <name name-style="western"><surname>Fragala-Pinkham</surname> <given-names>MA</given-names></name>. <article-title>Interpreting change scores of tests and measures used in physical therapy</article-title>. <source>Phys Ther</source>. <year>2006</year>;<volume>86</volume>(<issue>5</issue>):<fpage>735</fpage>–<lpage>743</lpage>. <object-id pub-id-type="pmid">16649896</object-id></mixed-citation></ref>
<ref id="pone.0313320.ref020"><label>20</label><mixed-citation publication-type="journal" xlink:type="simple"><name name-style="western"><surname>Giavarina</surname> <given-names>D.</given-names></name> <article-title>Understanding Bland Altman analysis</article-title>. <source>Biochem Med (Zagreb).</source> <year>2015</year>;<volume>25</volume>(<issue>2</issue>):<fpage>141</fpage>–<lpage>151</lpage>. <comment>doi: <ext-link ext-link-type="uri" xlink:href="https://doi.org/10.11613/BM.2015.015" xlink:type="simple">10.11613/BM.2015.015</ext-link></comment> <object-id pub-id-type="pmid">26110027</object-id></mixed-citation></ref>
<ref id="pone.0313320.ref021"><label>21</label><mixed-citation publication-type="journal" xlink:type="simple"><name name-style="western"><surname>Silver</surname> <given-names>B</given-names></name>, <name name-style="western"><surname>Wilson</surname> <given-names>PB</given-names></name>. <article-title>Reliability and minimal detectable change of the Styku 3D Body Scanner.</article-title> <source>Meas Phys Educ Exerc Sci</source>. <year>2020</year>;<volume>24</volume>(<issue>3</issue>):<fpage>165</fpage>–<lpage>171</lpage>.</mixed-citation></ref>
<ref id="pone.0313320.ref022"><label>22</label><mixed-citation publication-type="journal" xlink:type="simple"><name name-style="western"><surname>Tucker</surname> <given-names>LA</given-names></name>, <name name-style="western"><surname>Lecheminant</surname> <given-names>JD</given-names></name>, <name name-style="western"><surname>Bailey</surname> <given-names>BW</given-names></name>. <article-title>Test-retest reliability of the Bod Pod: The effect of multiple assessments.</article-title> <source>Percept Mot Skills</source>. <year>2014</year>;<volume>118</volume>(<issue>2</issue>):<fpage>563</fpage>–<lpage>570</lpage>. <comment>doi: <ext-link ext-link-type="uri" xlink:href="https://doi.org/10.2466/03.PMS.118k15w5" xlink:type="simple">10.2466/03.PMS.118k15w5</ext-link></comment> <object-id pub-id-type="pmid">24897887</object-id></mixed-citation></ref>
<ref id="pone.0313320.ref023"><label>23</label><mixed-citation publication-type="other" xlink:type="simple">Pranavmurthi V, Webb C, Hutzley V, Smith R, Strang A. Independent validation of a commercial saliva osmometer for hydration monitoring. Available from: <ext-link ext-link-type="uri" xlink:href="https://www.mx3diagnostics.com/files/files/USAF%20abstract.pdf" xlink:type="simple">https://www.mx3diagnostics.com/files/files/USAF%20abstract.pdf</ext-link>.</mixed-citation></ref>
<ref id="pone.0313320.ref024"><label>24</label><mixed-citation publication-type="other" xlink:type="simple">Kwan P. Independent validation of salivary osmolarity measures made by the MX3 Hydration Testing System compared to a laboratory grade osmometer. Available from: <ext-link ext-link-type="uri" xlink:href="https://www.mx3diagnostics.com/files/files/au/z2_independent-validation-report.pdf" xlink:type="simple">https://www.mx3diagnostics.com/files/files/au/z2_independent-validation-report.pdf</ext-link>.</mixed-citation></ref>
<ref id="pone.0313320.ref025"><label>25</label><mixed-citation publication-type="journal" xlink:type="simple"><name name-style="western"><surname>Fischer</surname> <given-names>D</given-names></name>, <name name-style="western"><surname>Ship</surname> <given-names>JA</given-names></name>. <article-title>The effect of dehydration on parotid salivary gland function</article-title>. <source>Spec Care Dentist</source>. <year>1997</year>;<volume>17</volume>(<issue>2</issue>):<fpage>58</fpage>–<lpage>64</lpage>. <comment>doi: <ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1111/j.1754-4505.1997.tb00868.x" xlink:type="simple">10.1111/j.1754-4505.1997.tb00868.x</ext-link></comment> <object-id pub-id-type="pmid">9582701</object-id></mixed-citation></ref>
</ref-list>
</back>
<sub-article article-type="aggregated-review-documents" id="pone.0313320.r001" specific-use="decision-letter">
<front-stub>
<article-id pub-id-type="doi">10.1371/journal.pone.0313320.r001</article-id>
<title-group>
<article-title>Decision Letter 0</article-title>
</title-group>
<contrib-group>
<contrib contrib-type="author">
<name name-style="western">
<surname>Adams</surname>
<given-names>William M.</given-names>
</name>
<role>Academic Editor</role>
</contrib>
</contrib-group>
<permissions>
<copyright-year>2024</copyright-year>
<copyright-holder>William M. Adams</copyright-holder>
<license xlink:href="http://creativecommons.org/licenses/by/4.0/">
<license-p>This is an open access article distributed under the terms of the <ext-link ext-link-type="uri" xlink:href="http://creativecommons.org/licenses/by/4.0/" xlink:type="simple">Creative Commons Attribution License</ext-link>, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.</license-p>
</license>
</permissions>
<related-object document-id="10.1371/journal.pone.0313320" document-id-type="doi" document-type="article" id="rel-obj001" link-type="peer-reviewed-article"/>
<custom-meta-group>
<custom-meta>
<meta-name>Submission Version</meta-name>
<meta-value>0</meta-value>
</custom-meta>
</custom-meta-group>
</front-stub>
<body>
<p>
<named-content content-type="letter-date">10 Sep 2024</named-content>
</p>
<p><!-- <div> -->PONE-D-24-29326<!-- </div> --><!-- <div> -->Reliability and Minimal Detectable Change of the MX3 Hydration Testing System<!-- </div> --><!-- <div> -->PLOS ONE</p>
<p>Dear Dr. wilson,</p>
<p>Thank you for submitting your manuscript to PLOS ONE. After careful consideration, we feel that it has merit but does not fully meet PLOS ONE’s publication criteria as it currently stands. Therefore, we invite you to submit a revised version of the manuscript that addresses the points raised during the review process.</p>
<p>Please submit your revised manuscript by Oct 25 2024 11:59PM. If you will need more time than this to complete your revisions, please reply to this message or contact the journal office at <email xlink:type="simple">plosone@plos.org</email>. When you're ready to submit your revision, log on to <ext-link ext-link-type="uri" xlink:href="https://www.editorialmanager.com/pone/" xlink:type="simple">https://www.editorialmanager.com/pone/</ext-link> and select the 'Submissions Needing Revision' folder to locate your manuscript file.</p>
<p>Please include the following items when submitting your revised manuscript:<!-- </div> --><list list-type="bullet"><list-item><p>A rebuttal letter that responds to each point raised by the academic editor and reviewer(s). You should upload this letter as a separate file labeled 'Response to Reviewers'.</p></list-item><list-item><p>A marked-up copy of your manuscript that highlights changes made to the original version. You should upload this as a separate file labeled 'Revised Manuscript with Track Changes'.</p></list-item><list-item><p>An unmarked version of your revised paper without tracked changes. You should upload this as a separate file labeled 'Manuscript'.</p></list-item></list></p>
<p>If you would like to make changes to your financial disclosure, please include your updated statement in your cover letter. Guidelines for resubmitting your figure files are available below the reviewer comments at the end of this letter.</p>
<p>If applicable, we recommend that you deposit your laboratory protocols in protocols.io to enhance the reproducibility of your results. Protocols.io assigns your protocol its own identifier (DOI) so that it can be cited independently in the future. For instructions see: <ext-link ext-link-type="uri" xlink:href="https://journals.plos.org/plosone/s/submission-guidelines#loc-laboratory-protocols" xlink:type="simple">https://journals.plos.org/plosone/s/submission-guidelines#loc-laboratory-protocols</ext-link>. Additionally, PLOS ONE offers an option for publishing peer-reviewed Lab Protocol articles, which describe protocols hosted on protocols.io. Read more information on sharing protocols at <ext-link ext-link-type="uri" xlink:href="https://plos.org/protocols?utm_medium=editorial-email&amp;utm_source=authorletters&amp;utm_campaign=protocols" xlink:type="simple">https://plos.org/protocols?utm_medium=editorial-email&amp;utm_source=authorletters&amp;utm_campaign=protocols</ext-link>.</p>
<p>We look forward to receiving your revised manuscript.</p>
<p>Kind regards,</p>
<p>William M. Adams</p>
<p>Academic Editor</p>
<p>PLOS ONE</p>
<p><!-- <div> --><!-- <span style="font-size: 13px;"> -->Journal Requirements:<!-- </span> --><!-- </div> --><!-- <div> --> <!-- </div> --><!-- <div> --><!-- <span style="font-size: 13px;"> -->When submitting your revision, we need you to address these additional requirements.<!-- </span> --><!-- </div> --><!-- <div> --> <!-- </div> --><!-- <div> --><!-- <span style="font-size: 13px;"> -->1. Please ensure that your manuscript meets PLOS ONE's style requirements, including those for file naming. The PLOS ONE style templates can be found at <!-- </span> --><!-- </div> --><!-- <div> --><!-- <span style="font-size: 13px;"> --><ext-link ext-link-type="uri" xlink:href="https://journals.plos.org/plosone/s/file?id=wjVg/PLOSOne_formatting_sample_main_body.pdf" xlink:type="simple">https://journals.plos.org/plosone/s/file?id=wjVg/PLOSOne_formatting_sample_main_body.pdf</ext-link> and <!-- </span> --><!-- </div> --><!-- <div> --><!-- <span style="font-size: 13px;"> --><ext-link ext-link-type="uri" xlink:href="https://journals.plos.org/plosone/s/file?id=ba62/PLOSOne_formatting_sample_title_authors_affiliations.pdf" xlink:type="simple">https://journals.plos.org/plosone/s/file?id=ba62/PLOSOne_formatting_sample_title_authors_affiliations.pdf</ext-link><!-- </span> --></p>
<p>[Note: HTML markup is below. Please do not edit.]</p>
<p>Reviewers' comments:</p>
<p>Reviewer's Responses to Questions<!-- </div> --></p>
<p><!-- <font color="black"> --><bold>Comments to the Author</bold></p>
<p>1. Is the manuscript technically sound, and do the data support the conclusions?</p>
<p>The manuscript must describe a technically sound piece of scientific research with data that supports the conclusions. Experiments must have been conducted rigorously, with appropriate controls, replication, and sample sizes. The conclusions must be drawn appropriately based on the data presented. <!-- </font> --></p>
<p>Reviewer #1: Yes</p>
<p>Reviewer #2: Partly</p>
<p>**********</p>
<p><!-- <font color="black"> -->2. Has the statistical analysis been performed appropriately and rigorously? <!-- </font> --></p>
<p>Reviewer #1: Yes</p>
<p>Reviewer #2: Yes</p>
<p>**********</p>
<p><!-- <font color="black"> -->3. Have the authors made all data underlying the findings in their manuscript fully available?</p>
<p>The <ext-link ext-link-type="uri" xlink:href="http://www.plosone.org/static/policies.action#sharing" xlink:type="simple">PLOS Data policy</ext-link> requires authors to make all data underlying the findings described in their manuscript fully available without restriction, with rare exception (please refer to the Data Availability Statement in the manuscript PDF file). The data should be provided as part of the manuscript or its supporting information, or deposited to a public repository. For example, in addition to summary statistics, the data points behind means, medians and variance measures should be available. If there are restrictions on publicly sharing data—e.g. participant privacy or use of data from a third party—those must be specified.<!-- </font> --></p>
<p>Reviewer #1: Yes</p>
<p>Reviewer #2: Yes</p>
<p>**********</p>
<p><!-- <font color="black"> -->4. Is the manuscript presented in an intelligible fashion and written in standard English?</p>
<p>PLOS ONE does not copyedit accepted manuscripts, so the language in submitted articles must be clear, correct, and unambiguous. Any typographical or grammatical errors should be corrected at revision, so please note any specific errors here.<!-- </font> --></p>
<p>Reviewer #1: Yes</p>
<p>Reviewer #2: Yes</p>
<p>**********</p>
<p><!-- <font color="black"> -->5. Review Comments to the Author</p>
<p>Please use the space provided to explain your answers to the questions above. You may also include additional comments for the author, including concerns about dual publication, research ethics, or publication ethics. (Please upload your review as an attachment if it exceeds 20,000 characters)<!-- </font> --></p>
<p>Reviewer #1: Congratulations on your submission. This manuscript assessed the reliability of the MX3 Hydration Testing system among adults. The authors did an excellent job establishing the reliability of this device under the field conditions under which the device is typically used. I have only some minor comments to enhance the quality of the paper:</p>
<p>-Some have argued an equivalence test, such as the two-one-sided (TOST) test is preferable to a t-test in studies that are specifically evaluating equivalence. Rather than running a paired t-test for comparison, I suggest completing the TOST procedure in order to determine statistical equivalence between these repeated measures of the MX3 device.</p>
<p>Lakens D, Scheel AM, Isager PM. Equivalence Testing for Psychological Research: A Tutorial. Advances in Methods and Practices in Psychological Science. 2018;1(2):259-269. doi:10.1177/2515245918770963</p>
<p>-In table 1, can you please also provide the 95% confidence interval for the ICC?</p>
<p>-In the methods can you provide a little more detail on the questionnaire used to determine fluid intake from the four hours prior?</p>
<p>-Did you test for proportional bias in your Bland-Altman analysis?</p>
<p>-Do you have any additional information about the context in which the measurements were taken and if this was related in any way to the agreement? For example, some participants were likely post-workout at the gym or weightlifting event where the data were collected as compared to some other scenarios where a disturbance to hydration status may have been less likely. Can you comment on if you think the context would influence the agreement?</p>
<p>Reviewer #2: Summary and Overall Impression</p>
<p>This study investigates the within-day, test-retest reliability and minimal detectable change (MDC) of the MX3 Hydration Testing System for measuring saliva osmolality. The research addresses an important gap in the literature about the reliability of this portable device for assessing hydration status. Overall, the manuscript is structured well to address the need for confirming the use of the MX3 HTS for field-based hydration assessment and provides valuable information for interested researchers and practitioners. The study's strengths include a clear research question, adequate methods, and highlights practical implications of the findings. However, there are some areas that authors are highly encouraged to consider revising before agreeing on the final draft of the manuscript for publication.</p>
<p>**********</p>
<p><!-- <font color="black"> -->6. PLOS authors have the option to publish the peer review history of their article (<ext-link ext-link-type="uri" xlink:href="https://journals.plos.org/plosone/s/editorial-and-peer-review-process#loc-peer-review-history" xlink:type="simple">what does this mean?</ext-link>). If published, this will include your full peer review and any attached files.</p>
<p>If you choose “no”, your identity will remain anonymous but your review may still be made public.</p>
<p><bold>Do you want your identity to be public for this peer review?</bold> For information about this choice, including consent withdrawal, please see our <ext-link ext-link-type="uri" xlink:href="https://www.plos.org/privacy-policy" xlink:type="simple">Privacy Policy</ext-link>.<!-- </font> --></p>
<p>Reviewer #1: No</p>
<p>Reviewer #2: <bold>Yes: </bold>Bahman Adlou</p>
<p>**********</p>
<p>[NOTE: If reviewer comments were submitted as an attachment file, they will be attached to this email and accessible via the submission site. Please log into your account, locate the manuscript record, and check for the action link "View Attachments". If this link does not appear, there are no attachment files.]</p>
<p>While revising your submission, please upload your figure files to the Preflight Analysis and Conversion Engine (PACE) digital diagnostic tool, <ext-link ext-link-type="uri" xlink:href="https://pacev2.apexcovantage.com/" xlink:type="simple">https://pacev2.apexcovantage.com/</ext-link>. PACE helps ensure that figures meet PLOS requirements. To use PACE, you must first register as a user. Registration is free. Then, login and navigate to the UPLOAD tab, where you will find detailed instructions on how to use the tool. If you encounter any issues or have any questions when using PACE, please email PLOS at <email xlink:type="simple">figures@plos.org</email>. Please note that Supporting Information files do not need this step.</p>
<supplementary-material id="pone.0313320.s002" mimetype="application/vnd.openxmlformats-officedocument.wordprocessingml.document" position="float" xlink:href="info:doi/10.1371/journal.pone.0313320.s002" xlink:type="simple">
<label>Attachment</label>
<caption>
<p>Submitted filename: <named-content content-type="submitted-filename">PONE-D-24-29326_Review.docx</named-content></p>
</caption>
</supplementary-material>
</body>
</sub-article>
<sub-article article-type="author-comment" id="pone.0313320.r002">
<front-stub>
<article-id pub-id-type="doi">10.1371/journal.pone.0313320.r002</article-id>
<title-group>
<article-title>Author response to Decision Letter 0</article-title>
</title-group>
<related-object document-id="10.1371/journal.pone.0313320" document-id-type="doi" document-type="peer-reviewed-article" id="rel-obj002" link-type="rebutted-decision-letter" object-id="10.1371/journal.pone.0313320.r001" object-id-type="doi" object-type="decision-letter"/>
<custom-meta-group>
<custom-meta>
<meta-name>Submission Version</meta-name>
<meta-value>1</meta-value>
</custom-meta>
</custom-meta-group>
</front-stub>
<body>
<p>
<named-content content-type="author-response-date">30 Sep 2024</named-content>
</p>
<p>Reviewer #1</p>
<p>Comment: Congratulations on your submission. This manuscript assessed the reliability of the MX3 Hydration Testing system among adults. The authors did an excellent job establishing the reliability of this device under the field conditions under which the device is typically used. I have only some minor comments to enhance the quality of the paper:</p>
<p>• Response: We appreciate the positive review and helpful comments from the reviewer. We feel the revisions made, based off their review, have improved the quality of the manuscript. </p>
<p>Comment: Some have argued an equivalence test, such as the two-one-sided (TOST) test is preferable to a t-test in studies that are specifically evaluating equivalence. Rather than running a paired t-test for comparison, I suggest completing the TOST procedure in order to determine statistical equivalence between these repeated measures of the MX3 device.</p>
<p>Lakens D, Scheel AM, Isager PM. Equivalence Testing for Psychological Research: A Tutorial. Advances in Methods and Practices in Psychological Science. 2018;1(2):259-269. doi:10.1177/2515245918770963</p>
<p>• Response: Thanks for the suggestion. We have carried out a two-one-sided test (TOST), which indicates that there was equivalence between the two SOSM measurements (both tests for upper and lower bounds had a p &lt; 0.001).</p>
<p>Comment: In table 1, can you please also provide the 95% confidence interval for the ICC?</p>
<p>• Response: We have added the 95% CI for the ICC.</p>
<p>Comment: In the methods can you provide a little more detail on the questionnaire used to determine fluid intake from the four hours prior?</p>
<p>• Response: We have provided additional information on the questionnaire, particularly as it relates to the assessment of exercise/physical activity.</p>
<p>Comment: Did you test for proportional bias in your Bland-Altman analysis?</p>
<p>• Response: Thanks for the suggestion. This has been added to the manuscript. We fitted a regression line to the Bland-Altman plot and used it to test for proportional bias. The regression co-efficient was 0.07 with a 95% CI that covered 0 (-0.11, 0.24), indicating an absence of obvious proportional bias. However, in Figure 2, which shows the regression of the first and second SOSM measurements along with a line of identity, there did appear to be some evidence of proportional bias, with a co-efficient of 0.71 (95% CI: 0.56, 0.85) that was different from 1.0.  </p>
<p>Comment: Do you have any additional information about the context in which the measurements were taken and if this was related in any way to the agreement? For example, some participants were likely post-workout at the gym or weightlifting event where the data were collected as compared to some other scenarios where a disturbance to hydration status may have been less likely. Can you comment on if you think the context would influence the agreement?</p>
<p>• Response: We did not systematically assess exercise engagement in the hours prior to data collection. Given that some participants were likely to have exercised in some manner prior to data collection, it may be expected that SOSM would be increased in those individuals (Walsh et al., 2004; <ext-link ext-link-type="uri" xlink:href="https://www.sciencedirect.com/science/article/abs/pii/S0003996903002127" xlink:type="simple">https://www.sciencedirect.com/science/article/abs/pii/S0003996903002127</ext-link>). Regardless, two samples were collected only a few minutes apart, so we doubt that reliability is likely to be substantially impacted in this context. That being said, we cannot fully rule out the possibility that the strength of reliability may be impacted by hydration status. For example, if a person is hypohydrated, they could potentially have more difficulty producing saliva consistently. As such, we have added the following text to the limitations section: “Another limitation is that there was no systematic assessment of exercise in the hours prior to the data collection. Some participants were likely to have exercised, which could raise SOSM and theoretically affect the reliability of the MX3. For example, if a person is hypohydrated due to exercise, they may have more difficulty producing saliva consistently [25].”</p>
<p>Reviewer #2</p>
<p>Comment: The rationale for the approximately 5-minute gap between measurements should be better explained. Was this based on previous literature or practical considerations? While the study did not explicitly state the directed use of MX3 HTS for athletic population, it seemed as implied throughout the manuscript. To which athletes does this approx. 5 min gap apply? What age, or competitive level? Was this applied in validation of other field-based measures? </p>
<p>• Response: This 3-5-minute gap was chosen for practical and methodological purposes–not particularly developed for any type or group of athletes. We wanted this period to be short so that actual biological changes in hydration status would be minimal. Between measurements, body composition was assessed using a portable bioelectrical impedance analysis scale. The resulting 3-5-minute gap between measures was short enough to not expect substantial, real changes in hydration status. When assessing reliability, the period between measurements should be selected so that there is minimal real biological change. </p>
<p>Comment: The authors sampled a large and heterogeneous population, which is commendable. However, the study does not include an analysis of inter-rater reliability, despite using three investigators. Given the sample size, it would have been feasible to conduct ICC and MDC analyses within each rater or at least assess inter-rater reliability to ensure consistency across different users. This is particularly important since recent literature by Ely et al. (2011) highlighted the limitation of salivary osmolality as a hydration marker, including high inter-individual variability. The manuscript could discuss how the MX3 HTS addresses or accounts for these limitations. </p>
<p>• Response: The vast majority of measurements (&gt;90%) were carried out by one investigator. While all three investigators used the MX3 device at some point, there is not adequate data from the second and third investigators to assess inter-rater reliability. All three investigators followed a standard sampling protocol recommended by MX3 (<ext-link ext-link-type="uri" xlink:href="https://www.youtube.com/watch?v=bFPtJGFG13c" xlink:type="simple">https://www.youtube.com/watch?v=bFPtJGFG13c</ext-link>) and practiced using the MX3 on multiple occasions prior to using it for study data collection. The sampling procedure is not particularly complicated, so we do not believe there is likely to be much of an inter-rater effect. Nonetheless, we have suggested this as an area of future research.</p>
<p>Comment: There are concerns regarding the testing protocol. The manuscript does not specify what participants did during the 3-5-minute break between tests, nor whether they participated in strenuous exercise or any physical activity before the tests. Additionally, the time of day when testing was conducted is not described, which could significantly impact saliva osmolality values. Collecting data on diet within four hours prior to testing could have provided insights into how specific food content might affect the accuracy of the measurements.</p>
<p>• Response: We did in fact specify what participants did between the two measurements. As described in the original manuscript, all that participants did during the 3-5-minute gap between measures was step on a BIA device and have their height measured. During that time period, no participant engaged in exercise. </p>
<p>• Response: While data on diet within four hours leading up to testing could have provided insights into how food choices and content might affect SOSM, this would be unlikely to affect the reliability of the measurements taken and would not, in our minds, justify the additional time/effort required from participants.</p>
<p>Comment: The authors could have considered using mixed models to account for individual differences in their heterogeneous population, such as age, physical activity level, and race. This approach could have provided a more nuanced understanding of how these factors impact the device's reliability and improved the MDC analysis.</p>
<p>• Response: We appreciate that there are many different analytical approaches to use in any given study. However, we feel that it is generally advisable to use the a priori planned analysis to avoid problems that arise from conducting multiple unplanned analyses (e.g., type 1 error increases). Given that a mixed-model approach was not planned prior to the study being conducted, we have reservations about doing that sort of analysis now. In addition, only a small minority of our participants (&lt;10%) were under the age of 50 and &lt;25% were non-white, meaning we wouldn’t have good statistical power to evaluate how those factors impact the results. </p>
<p>Comment: Some of the references are outdated. While new evidence does not debunk the previous findings, they do make the context more applicable to our current generation of physically active population, such as those in the study.</p>
<p>• Response: A few older references have been switched out for newer ones. We are open to considering any relevant specific suggestions the reviewer may have related to references.</p>
<p>Comment: You could break some of the longer sentences in the first paragraph into smaller segments for better readability. </p>
<p>• Response: We have broken up a few sentences throughout the manuscript. If the reviewer has additional specific suggestions, we are happy to consider them. </p>
<p>Comment: Additional context on the importance of field-based hydration assessment in various settings (e.g., sports, military, occupational health) would strengthen the rationale for the study. The population was reviewed in the later segments of the manuscripts, but limited supporting literature were included in either Introduction or Discussion for that. Please consider expanding on the practical implications of the MDC values for different user groups I, or refrain from including them later in the manuscript.</p>
<p>• Response: We have deleted the text that refers to occupational and military settings.</p>
<p>Comment: Clarify whether all participants were assessed at the same time of day, as this could impact SOSM measurements.</p>
<p>• Response: Thanks for the suggestion. We have added an additional analysis (t-test comparing SOSM values between morning and afternoon samples) based on sampling time of day. There was no significant difference in average SOSM between those sampled in the morning versus those sampled in the afternoon (65.4±19.7 vs. 64.6±15.8 mOsm; t=0.203, p=0.839, Cohen’s d=0.05).</p>
<p>Comment: Provide more detail on the training or standardization of the three investigators who used the MX3 HTS. Where are they athletic trainers, dietitians, other allied professionals, or trained research staff? Is the training provided by the device company and was compliance checked?</p>
<p>• Response: Two of the investigators are Registered Dietitians, one being an associate professor of exercise science and the other being a PhD student. The third investigator is an undergraduate exercise science student trained by both dietitians prior to any data collection. Before collecting any study data, all three investigators practiced sampling on multiple occasions according to MX3 HTS guidelines (<ext-link ext-link-type="uri" xlink:href="https://www.youtube.com/watch?v=bFPtJGFG13c" xlink:type="simple">https://www.youtube.com/watch?v=bFPtJGFG13c</ext-link>). No formal training was provided by the company, as the sampling technique is relatively straightforward (<ext-link ext-link-type="uri" xlink:href="https://www.youtube.com/watch?v=bFPtJGFG13c" xlink:type="simple">https://www.youtube.com/watch?v=bFPtJGFG13c</ext-link>). </p>
<p>Comment: Include effect sizes alongside p-values where appropriate to give a better sense of the magnitude of differences.</p>
<p>• Response: Thanks for the suggestion. We have included Cohen d values alongside the t-tests that were carried out. </p>
<p>Comment: The authors referred to themselves as “the authors of the study” in the beginning, and then referred to themselves as “we.” Review and proofread the manuscript to stay consistent.</p>
<p>• Response: This change has been made.</p>
<supplementary-material id="pone.0313320.s003" mimetype="application/vnd.openxmlformats-officedocument.wordprocessingml.document" position="float" xlink:href="info:doi/10.1371/journal.pone.0313320.s003" xlink:type="simple">
<label>Attachment</label>
<caption>
<p>Submitted filename: <named-content content-type="submitted-filename">Response to Reviewers_Final_9.23.2024.docx</named-content></p>
</caption>
</supplementary-material>
</body>
</sub-article>
<sub-article article-type="aggregated-review-documents" id="pone.0313320.r003" specific-use="decision-letter">
<front-stub>
<article-id pub-id-type="doi">10.1371/journal.pone.0313320.r003</article-id>
<title-group>
<article-title>Decision Letter 1</article-title>
</title-group>
<contrib-group>
<contrib contrib-type="author">
<name name-style="western">
<surname>Adams</surname>
<given-names>William M.</given-names>
</name>
<role>Academic Editor</role>
</contrib>
</contrib-group>
<permissions>
<copyright-year>2024</copyright-year>
<copyright-holder>William M. Adams</copyright-holder>
<license xlink:href="http://creativecommons.org/licenses/by/4.0/">
<license-p>This is an open access article distributed under the terms of the <ext-link ext-link-type="uri" xlink:href="http://creativecommons.org/licenses/by/4.0/" xlink:type="simple">Creative Commons Attribution License</ext-link>, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.</license-p>
</license>
</permissions>
<related-object document-id="10.1371/journal.pone.0313320" document-id-type="doi" document-type="article" id="rel-obj003" link-type="peer-reviewed-article"/>
<custom-meta-group>
<custom-meta>
<meta-name>Submission Version</meta-name>
<meta-value>1</meta-value>
</custom-meta>
</custom-meta-group>
</front-stub>
<body>
<p>
<named-content content-type="letter-date">23 Oct 2024</named-content>
</p>
<p>Reliability and Minimal Detectable Change of the MX3 Hydration Testing System</p>
<p>PONE-D-24-29326R1</p>
<p>Dear Dr. wilson,</p>
<p>We’re pleased to inform you that your manuscript has been judged scientifically suitable for publication and will be formally accepted for publication once it meets all outstanding technical requirements.</p>
<p>Within one week, you’ll receive an e-mail detailing the required amendments. When these have been addressed, you’ll receive a formal acceptance letter and your manuscript will be scheduled for publication.</p>
<p>An invoice will be generated when your article is formally accepted. Please note, if your institution has a publishing partnership with PLOS and your article meets the relevant criteria, all or part of your publication costs will be covered. Please make sure your user information is up-to-date by logging into Editorial Manager at <ext-link ext-link-type="uri" xlink:href="https://www.editorialmanager.com/pone/" xlink:type="simple">Editorial Manager®</ext-link> and clicking the ‘Update My Information' link at the top of the page. If you have any questions relating to publication charges, please contact our Author Billing department directly at <email xlink:type="simple">authorbilling@plos.org</email>.</p>
<p>If your institution or institutions have a press office, please notify them about your upcoming paper to help maximize its impact. If they’ll be preparing press materials, please inform our press team as soon as possible -- no later than 48 hours after receiving the formal acceptance. Your manuscript will remain under strict press embargo until 2 pm Eastern Time on the date of publication. For more information, please contact <email xlink:type="simple">onepress@plos.org</email>.</p>
<p>Kind regards,</p>
<p>William M. Adams</p>
<p>Academic Editor</p>
<p>PLOS ONE</p>
<p>Additional Editor Comments (optional):</p>
<p>Reviewers' comments:</p>
<p>Reviewer's Responses to Questions</p>
<p><!-- <font color="black"> --><bold>Comments to the Author</bold></p>
<p>1. If the authors have adequately addressed your comments raised in a previous round of review and you feel that this manuscript is now acceptable for publication, you may indicate that here to bypass the “Comments to the Author” section, enter your conflict of interest statement in the “Confidential to Editor” section, and submit your "Accept" recommendation.<!-- </font> --></p>
<p>Reviewer #1: All comments have been addressed</p>
<p>Reviewer #2: All comments have been addressed</p>
<p>**********</p>
<p><!-- <font color="black"> -->2. Is the manuscript technically sound, and do the data support the conclusions?</p>
<p>The manuscript must describe a technically sound piece of scientific research with data that supports the conclusions. Experiments must have been conducted rigorously, with appropriate controls, replication, and sample sizes. The conclusions must be drawn appropriately based on the data presented. <!-- </font> --></p>
<p>Reviewer #1: Yes</p>
<p>Reviewer #2: Yes</p>
<p>**********</p>
<p><!-- <font color="black"> -->3. Has the statistical analysis been performed appropriately and rigorously? <!-- </font> --></p>
<p>Reviewer #1: Yes</p>
<p>Reviewer #2: N/A</p>
<p>**********</p>
<p><!-- <font color="black"> -->4. Have the authors made all data underlying the findings in their manuscript fully available?</p>
<p>The <ext-link ext-link-type="uri" xlink:href="http://www.plosone.org/static/policies.action#sharing" xlink:type="simple">PLOS Data policy</ext-link> requires authors to make all data underlying the findings described in their manuscript fully available without restriction, with rare exception (please refer to the Data Availability Statement in the manuscript PDF file). The data should be provided as part of the manuscript or its supporting information, or deposited to a public repository. For example, in addition to summary statistics, the data points behind means, medians and variance measures should be available. If there are restrictions on publicly sharing data—e.g. participant privacy or use of data from a third party—those must be specified.<!-- </font> --></p>
<p>Reviewer #1: Yes</p>
<p>Reviewer #2: Yes</p>
<p>**********</p>
<p><!-- <font color="black"> -->5. Is the manuscript presented in an intelligible fashion and written in standard English?</p>
<p>PLOS ONE does not copyedit accepted manuscripts, so the language in submitted articles must be clear, correct, and unambiguous. Any typographical or grammatical errors should be corrected at revision, so please note any specific errors here.<!-- </font> --></p>
<p>Reviewer #1: Yes</p>
<p>Reviewer #2: Yes</p>
<p>**********</p>
<p><!-- <font color="black"> -->6. Review Comments to the Author</p>
<p>Please use the space provided to explain your answers to the questions above. You may also include additional comments for the author, including concerns about dual publication, research ethics, or publication ethics. (Please upload your review as an attachment if it exceeds 20,000 characters)<!-- </font> --></p>
<p>Reviewer #1: Thank you for addressing all of my comments. I recommend this manuscript be accepted for publication.</p>
<p>Reviewer #2: Congratulations to the authors for conducting this research project and delivering the results to improve the scientific community. There were major revisions done to the manuscripts that could improve the interaction with the data and the findings. Thank you for all your work and attention to detail.</p>
<p>The authors' responses to the revision requests were very appropriate and thorough where applicable. I would recommend (though not necessary) to consider a minor revision:</p>
<p>1. Given that the company has made a great effort to create educational content and tutorial videos for using their device, it could be appropriate to include [in the method] that all users in this study followed the training materials. This serves as both a nod to the industry partner (and others) and a statement on how you opted to standardize the data collection procedure. This method of standardization is becoming more accepted as the industry partners are allocating a bigger budget on training materials.</p>
<p>**********</p>
<p><!-- <font color="black"> -->7. PLOS authors have the option to publish the peer review history of their article (<ext-link ext-link-type="uri" xlink:href="https://journals.plos.org/plosone/s/editorial-and-peer-review-process#loc-peer-review-history" xlink:type="simple">what does this mean?</ext-link>). If published, this will include your full peer review and any attached files.</p>
<p>If you choose “no”, your identity will remain anonymous but your review may still be made public.</p>
<p><bold>Do you want your identity to be public for this peer review?</bold> For information about this choice, including consent withdrawal, please see our <ext-link ext-link-type="uri" xlink:href="https://www.plos.org/privacy-policy" xlink:type="simple">Privacy Policy</ext-link>.<!-- </font> --></p>
<p>Reviewer #1: No</p>
<p>Reviewer #2: No</p>
<p>**********</p>
</body>
</sub-article>
<sub-article article-type="editor-report" id="pone.0313320.r004" specific-use="acceptance-letter">
<front-stub>
<article-id pub-id-type="doi">10.1371/journal.pone.0313320.r004</article-id>
<title-group>
<article-title>Acceptance letter</article-title>
</title-group>
<contrib-group>
<contrib contrib-type="author">
<name name-style="western">
<surname>Adams</surname>
<given-names>William M.</given-names>
</name>
<role>Academic Editor</role>
</contrib>
</contrib-group>
<permissions>
<copyright-year>2024</copyright-year>
<copyright-holder>William M. Adams</copyright-holder>
<license xlink:href="http://creativecommons.org/licenses/by/4.0/">
<license-p>This is an open access article distributed under the terms of the <ext-link ext-link-type="uri" xlink:href="http://creativecommons.org/licenses/by/4.0/" xlink:type="simple">Creative Commons Attribution License</ext-link>, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.</license-p>
</license>
</permissions>
<related-object document-id="10.1371/journal.pone.0313320" document-id-type="doi" document-type="article" id="rel-obj004" link-type="peer-reviewed-article"/>
</front-stub>
<body>
<p>
<named-content content-type="letter-date">11 Nov 2024</named-content>
</p>
<p>PONE-D-24-29326R1 </p>
<p>PLOS ONE</p>
<p>Dear Dr.  wilson, </p>
<p>I'm pleased to inform you that your manuscript has been deemed suitable for publication in PLOS ONE. Congratulations! Your manuscript is now being handed over to our production team.</p>
<p>At this stage, our production department will prepare your paper for publication. This includes ensuring the following:</p>
<p>* All references, tables, and figures are properly cited</p>
<p>* All relevant supporting information is included in the manuscript submission,</p>
<p>* There are no issues that prevent the paper from being properly typeset</p>
<p>If revisions are needed, the production department will contact you directly to resolve them. If no revisions are needed, you will receive an email when the publication date has been set. At this time, we do not offer pre-publication proofs to authors during production of the accepted work. Please keep in mind that we are working through a large volume of accepted articles, so please give us a few weeks to review your paper and let you know the next and final steps. </p>
<p>Lastly, if your institution or institutions have a press office, please let them know about your upcoming paper now to help maximize its impact. If they'll be preparing press materials, please inform our press team within the next 48 hours. Your manuscript will remain under strict press embargo until 2 pm Eastern Time on the date of publication. For more information, please contact <email xlink:type="simple">onepress@plos.org</email>.</p>
<p>If we can help with anything else, please email us at <email xlink:type="simple">customercare@plos.org</email>.</p>
<p>Thank you for submitting your work to PLOS ONE and supporting open access. </p>
<p>Kind regards, </p>
<p>PLOS ONE Editorial Office Staff</p>
<p>on behalf of</p>
<p>Dr. William M. Adams </p>
<p>Academic Editor</p>
<p>PLOS ONE</p>
</body>
</sub-article>
</article>